User's Manual

AUTEC - Air series
Technical data 3
LIRMHE00-00
2 Technical data
Power supply ............................................................................................. 24-240V (1A)
Power supply protection fuse ............................................................ 2A T 250V (5x20mm)
Digital inputs voltage .................................................................................... 24/48/110V
............................................................................................................................ 12/24V
Antenna ............................................................................................. internal or dedicated
STOP contacts rated current ......................................................................... 6A (250V )
STOP contacts protection fuses ....................................................... 6A T 250V (5x20mm)
SAFETY contacts rated current ................................................................... 10A (250V )
SAFETY contacts protection fuses ................................................. 10A T 250V (5x20mm)
Housing material .......................................................................................... PA 6 (20%fg)
Protection degree ....................................................................................... IP65 (NEMA 4)
Weight ........................................................................................................... 2.2kg (4.9Lb)
Command outputs are provided on the optional cards. Refer to technical data sheet for voltage
and current rating of command outputs.