User's Manual
Table Of Contents
- INDICE
- INDEX
AUTEC - AIR series
40 Receiving unit
Description of type L receiving unit
5.2 Description of type L receiving unit
5.3 Operation
5.3.1 Electronic module
The electronic module contains the address key, where the radio remote control configura-
tion data are also stored. The receiving unit cannot work without this address key.
5.3.2 DIP switches
DIP switch 1 is used to set the frequency band (see chapter 2)
DIP switch 2 shall always be set in the OFF position: do not modify it.
5.3.3 External light signals
The ENABLE LED is off: the receiving and transmitting units are not communicating.
The ENABLE LED blinks: the unit is ready to receive commands sent by the transmitting
unit.
The POWER LED is on: the receiving unit is powered on.
Electronic module
DIP switches
Internal light signals
Command outputs
SAFETY outputs
STOP outputs
Fuses of STOP circuit
Power supply fuse
Fuses of SAFETY circuit
Fuse F1 ......................................................................................... 1.6 A T 250 V (5x20 mm)
Fuses F2 and F3 ............................................................................. 4 A T 250 V (5x20 mm)
Fuses F4 and F5 ............................................................................. 4 A T 250 V (5x20 mm)
Connector for power supply