User's Manual
Table Of Contents
- INDICE
- INDEX
A8 transmitting unit 35
Operation
LIUAIR1AE3-01.fm
AUTEC - AIR series
Start up through customised PIN
If the risk assessment requires this, the PIN code may be modified to prevent unauthorised
use.
The procedure to set a customised PIN is provided in the document “Menu of Trans-
mitting Unit (MTU)”; you can find this document in the dedicated section on Autec's
website.
When the receiving unit is powered on, perform the following procedure:
1) press the START pushbutton until the green LED illuminates
2) press the pushbutton sequence PIN 1, PIN 2 and PIN 3 related to the PIN code provided
in the technical data sheet (if PIN 1 and/or PIN 3 is the START pushbutton, it is not to be
considered as part of the code sequence)
3) press the START pushbutton until the green LED blinks slowly.
4.2.2 Command activation
Press pushbuttons related to the commands you want to carry out.
4.2.3 Light signals during operations
Green LED
- steady on: transmitting and receiving unit do not com-
municate with each other
- blinks fast: the radio remote control starts when the
START pushbutton is pressed
- blinks slowly (one blink per second): it is possible to
send commands.
Red LED
- steady on at power on: the STOP pushbutton is activated or damaged
- blinks twice per second at power on: at least one of the commands is activated or damaged
- blinks 3 times per second at power on: the unit is discharged
- on for 2 s: the unit does not work correctly
- blinks slowly: approx. 4 h run time left
- blinks fast: 10 min run time left.
@
STARTFUNCT.
1
2
34
R
G
STOP
S1 S2
STARTFUNCT.
1
2
34
R
G
STOP
S1 S2
STARTFUNCT.
1
2
34
R
G
STOP
S1 S2
STARTFUNCT.
1
2
34
R
G
STOP
S1 S2
STARTFUNCT.
1
2
34
R
G
STOP
S1 S2
1) START 3) START
PIN 1 PIN 2 PIN 3
2) PIN
STOP
PD5580-00
Red LED
Green LED