PayspecialattentiontocurrentsandvoltagesowingintheSAFETYand
STOP outputs: they shall not exceed the maximum permitted values (see
technical data of the receiving unit).
To obtain the protection from unintended movements from the rest position,
connectthecontactoftheSAFETYrelayinserieswiththemovement
commands.
The STOP circuit in the receiving unit has two contacts connected in series
through a wire jumper (manufacturer's standard wiring). If the machine needs
a STOP circuit with two separate contacts (four wires), this bridge can be
removed. In this case, the installer is responsible for wiring in a way that
assures the required safety level.
Group the wiring away from the electronic module, in order to avoid
interferences and hazards related to electrical safety.
Evaluate the radio remote control's wiring and remember that if the output
dedicated to the machine's horn, siren or blinker is used for another command
due to application's and/or functional reasons, some procedures in the
“CongurationMenu”mayresultunavailablelateron.
To wire the terminals corresponding to the commands' outputs, to the STOP
outputs and to the SAFETY outputs, it is recommended to use a slot screwdriver