2 Technical data
Power supply ................................................................. 45-240V (max 40-264V 0.4A)
......................................................................................... or 12-24V (max 9-30V 1A)
Fuse F1 ......................................................................................... 1.6A T 250V (5x20mm)
Digital inputs voltage ................................................................... 10-60V (max 9-66V )
Antenna ............................................................................................. internal or dedicated
SAFETY contacts rated current ...................................................................... 4A (250V )
Fuses F2 and F3 .............................................................................. 4A T 250V (5x20mm)
STOP contacts rated current .......................................................................... 4A (250V )
Fuses F4 and F5 .............................................................................. 4A T 250V (5x20mm)
Commands rated current ................................................................................ 6A (250V )
Housing material .......................................................................................... PA 6 (20%fg)
Protection degree ....................................................................................... IP65 (NEMA 4)
Dimensions ................................................................ 123x202x83mm (4.84x7.95x3.23In)
Weight ........................................................................................................... 1.2kg (2.7Lb)
A 222 mm
B 106 mm
C 82 mm
D 213.5 mm
3 Technical data sheet
The technical data sheet contains the wiring diagram showing the connection between the
receiving unit and the machine. It also contains the transmitting unit con󰘰guration and shows
the matching between commands sent and machine functions/movements.
Each technical data sheet must be 󰘰lled in, checked and signed by the installer, who is
responsible for a correct wiring.
A copy of the technical data sheet must always be kept together with this manual (always
keep a copy of this data sheet for administrative purposes).
The wiring of the receiving unit outputs must always re󰄉ect the wiring
indicated in the technical data sheet.
AUTEC - AIR SERIES
Technical data 3
LIRGAE00-01