User's Manual
Table Of Contents
- Copertina esterna fronte LIMM&SA0-00.pdf
- Copertina interna fronte LIMM&SA0-00.pdf
- LIMM&SA0-00.pdf
- 1 Introduction
- 2 Transmitting units
- 3 Receiving unit
- 3.1 Description of the receiving unit
- 3.2 Inner parts of the “Master/Slave” receiving units
- 3.3 Inner parts of the “Master/Master” receiving units
- 3.4 General warnings for the installation of the receiving unit
- 3.5 Specific warnings for the installation of the receiving unit
- 3.6 Warnings for the maintenance of the receiving unit
- 3.7 External signal lights of the receiving unit
- 3.8 Internal signal lights of the receiving unit
- 4 Operating mode of “Master/Slave”
- 5 Operating mode of “Master/Master”
- 6 Operating mode of the transmitting units
- 7 Maintenance
- 8 Programming
- 9 Diagnostics
- bianca A4.pdf
- Copertina esterna retro LIMM&SA0-00.pdf
2 Transmitting units
- 8 -
LIMM&SA0-00.fm
Climatic
conditions
2.2 Description of MJ
(photos shown below only represent a possible configuration)
MJ
Technical data
Climatic
conditions
Temperature Relative Humidity Air Pressure
Working
Class 4K4H
-5°F to +130°F
(-20°C to +55°C)
Class 4K4H
4% to 100% (0,9 g/m
3
to 36 g/m
3
)
Class 4K4H
86 kPa to 106 kPa
Storage
Class 1K5
-40°F to + 160°F
(-40°C to +70°C)
Class 1K3
5% to 95% (1 g/m
3
to 29 g/m
3
)
Class 1K4
86 kPa to 106 kPa
Transportation
Class 2K3
-13°F to + 160°F
(-25°C to +70°C)
Class 2K3
95% (60 g/m
3
)
Class 2K3
70 kPa to 106 kPa
A
actuators (joysticks and selectors)
E
battery (at the bottom)
B
STOP pushbutton
F
signalling LED
C
pushbutton and/or selector (optional)
G
START pushbutton
D
identification plate and technical data
plate (in the battery housing)
H
starting keyswitch
H
F
E
D
C
B
A
G
Power supply (battery pack MBM06MH)
a
................................................ NiMH 7.2 Vdc
Antenna .................................................................................................... internal
Battery capacity with fully charged battery (continuous use at 20°C) ................ 14 hours
“Low battery” warning................................................................................. 3.5 min
Housing.............................................................................................PA 6 (20% fg)
Protection degree............................................................................... NEMA 4 [IP65]
Dimensions....................................................... 10" x 6.7" x 5"[255 x 170 x 126 mm]
Weight ............................................................................................2.9 lbs [1.3 kg]
Transmitting power (frequency 433 MHz).... meets FCC Part 15 for free-license operation
Transmitting power (frequency 870 MHz).... meets FCC Part 15 for free-license operation
a. refer to battery technical data in the battery charger manual.
Temperature Relative Humidity Air Pressure
Working
Class 4K4H
-5°F to +130°F
(-20°C to +55°C)
Class 4K4H
4% to 100% (0,9 g/m
3
to 36 g/m
3
)
Class 4K4H
86 kPa to 106 kPa
Storage
Class 1K5
-40°F to + 160°F
(-40°C to +70°C)
Class 1K3
5% to 95% (1 g/m
3
to 29 g/m
3
)
Class 1K4
86 kPa to 106 kPa
Transportation
Class 2K3
-13°F to + 160°F
(-25°C to +70°C)
Class 2K3
95% (60 g/m
3
)
Class 2K3
70 kPa to 106 kPa