User's Manual
Table Of Contents
Page 12 7 - Programming LI14CAA0-00 - AmEn.fm
7.2 PROGRAMMING THE E16B14AC MOTHER BOARD
DSW1
Dip switch programming shall correspond to
that given on the technical data sheet.
Dip switches 4-5-6 of the DSW1 group are
used to program some of the radio remote
control functions as illustrated in the following
table:
DSW1
PROG.
DIP
SWITCH
SEL.
POS.
FUNCTION
7.3 PROGRAMMING THE E16RI02B BUS BOARD
Autec programs this bus board and programming is recorded in the data memory.
DATA MEMORY
P1
4ON
RL3 held by RL2 (or RL1) and RL4 by RL3
*
*Once RL4 and RL3 have been activated after RL2 or RL1 (and therefore held by RL2 (or
RL1)) they can be easily disabled by activating them in the reverse order. The same
applies for RL8 and RL7 with RL5 (or RL6).
4 OFF disabled function
P2
5 ON RL7 held by RL5 (or RL6) and RL8 by RL7*
5 OFF disabled function
P3
6ON
If RL1 (or RL3) is active then RL2 and RL4 are disabled
If RL2 (or RL4) is active then RL1 and RL3 are disabled
6 OFF disabled function