User's Manual

Page 6 3 - Receiving unit Type R402 LI14CAA0-00 - AmEn.fm
3.1 RECEIVING UNIT TYPE R402 TECHNICAL DATA
Power supply
MIN. NOM. MAX.
Voltage (Vac) 18 25 30
25 35 42
36 50 62
70 110 132
Frequency (Hz) 50 60
Absorbed power (VA) 11
Climatic conditions
TEMPERATURE
RELATIVE
HUMIDITY
AIR PRESSURE
WORKING
Class 4K4H
-5°F to +160°F
(-20°C to +70°C)
Class 4K4H
4% to 100%
Class 4K4H
86 kPa to 106 kPa
STORAGE
Class 1K5
-40°F to + 160°F
(-40°C to +70°C)
Class 1K3
5% to 95%
Class 1K4
86 kPa to 106 kPa
TRANSPOR-
TATION
Class 2K3
-13°F to + 160°F
(-25°C to +70°C)
Class 2K3
95%
Class 2K3
70 kPa to 106 kPa
Antenna ......................................................................................................... dedicated
STOP contact rated current........................................................................ 4A (250Vac)
SAFETY contact rated current.................................................................... 4A (250Vac)
Command contact rated current ................................................................6A (250Vac)
*
Fuse F1 (POWER SUPPLY) ................................ 1.25A T 250V [0.2”x0.8” (5x20 mm)]
Fuse F2 and F3 (STOP circuit)...................................4A T 250V [0.2”x0.8” (5x20 mm)]
Fuse F4 and F5 (SAFETY circuit) ..............................4A T 250V [0.2”x0.8” (5x20 mm)]
Housing ....................................................................................................PA 6 (20% fg)
Protection degree ...................................................................................NEMA 4 (IP65)
Dimensions....................................................... (7.1”x9.1”x3.7”) [(180 x 230 x 95) mm]
Weight ................................................................................................... 5.7 lbs (2.6 kg)
*The maximum command contact rated current for the optional modules that may be present is given in the tech-