Receiving unit Type R202 TECHNICAL DATA
Power supply
Antenna
Max switching capacity of STOP contacts
Max switching capacity of SAFETY contacts
Max switching capacity of command contacts
Fuse F1 (STOP circuit)
Fuse F2 and F3 (SAFETY circuit)
Fuse F4 (POWER SUPPLY)
Working temperature
Housing
Minimum protection grade
Dimensions
Weight
*Capacity only valid if both terminals are used for each contact.
**If the radio remote control output have been cabled by Autec, please see technical data sheet.
12 or 24 Vdc ±25% (~15W)
integrated or dedicated
* 10A (30Vdc)
2 x 5A (30Vdc)
* 10A (30Vdc)**
10A T 250V (5x20 mm)
5A T 250V (5x20 mm)
1A (24Vdc) or 2A (12Vdc)T 250V (5x20 mm)
-4°F - +158°F
nylon (20% fg)
IP65
(202x381x91) mm
max 3,5 kg
The master board in this type of receiving unit is E16B22DC for configurations of up to 22
commands (plus extension interface card).