User's Manual
6
LIPCRE00-00
Malfunction signalled by the receiving unit
AUTEC - Dynamic Series
6 Malfunction signalled by the receiving unit
Use the light signals on the receiving unit to identify the radio remote control malfunction.
If the problem persists after the suggested solution has been carried out, contact the support
service of the machine manufacturer.
Signals Possible reason Solutions
The POWER LED is o.
The receiving unit is not
powered.
Disconnect the power supply
and restore it after 5 minutes
to make sure that a restorable
thermal fuse integrated in the
receiving unit has not been
activated.
Correctly plug in the
connecting plug and power on
the receiving unit.
The POWER LED is on. No radio link.
Bring the transmitting unit
closer to the receiving unit.
The ALARM LED blinks
once.
Error on the STOP outputs.
Make sure that fuses F3 and
F4 are intact.
Correctly plug in the
connecting plug.
Make sure that the STOP
outputs are wired correctly.
The ALARM LED blinks
twice.
Error on the SAFETY outputs.
Make sure that fuses F2 and
F5 are intact.
Correctly plug in the
connecting plug.
Make sure that the SAFETY
outputs are wired correctly.
The ALARM LED blinks three
times.
Error on the outputs
corresponding to direction
commands.
Contact the support service of
the machine manufacturer.
Make sure that the outputs of
direction commands are wired
correctly.
The ALARM LED is on.
The receiving unit does not
work correctly.
Contact the support service of
the machine manufacturer.