User's Manual
AUTEC - Dynamic Series
Plates 5
LIPCRE00-00
5.2 ALARM LED (red)
The ALARM LED warns about anomalies in the receiving unit.
The ALARM LED... Meaning
…is o The receiving unit works correctly.
... blinks once Error on the STOP outputs.
... blinks twice Error on the SAFETY outputs.
... blinks three times
Error on the outputs corresponding to direction
commands.
... is on The receiving unit does not work correctly.
5.3 STATUS LED (blue)
The STATUS LED warns about anomalies on the outputs or on the power supply and indicates
the reception of data from the transmitting unit.
The STATUS LED... Meaning
…is o No radio link.
... blinks slowly Over-voltage on power supply.
... blinks fast The receiving unit receives data from the transmitting unit.
... is on Over-current in one of the PWM analogue outputs.
5.4 LED RUN (green) e LED ERR (red)
RUN and ERR LED signals are congurable during the maschine installation: it is recommended
to respect the guidelines of the CANopen® standard, CiA recommendation 303-3.
5.5 SETUP LED (yellow)
SETUP LED signals are congurable during the machine installation.