User's Manual

AUTEC - Air series
Light signals 9
LILK6E00-02
The red LED [A]… Meaning
…is o󰓐. The transmitting unit works correctly.
... is steady on. At start-up, the STOP pushbutton is pressed or damaged.
... blinks twice per second.
At least one of the commands that were checked at start-
up is enabled or damaged (see technical data sheet).
... blinks three times per second. Atstart-up,thebatteryis󰘱at.
... is steady on for 2s. The transmitting unit does not work correctly.
… blinks slowly (one blink per
second).
The battery has less than 1h run time.
... blinks fast. The battery has a 10min run time.
LEDs … Meaning
… the green [B] and red [A] LEDs
are steady on
A wrong "Key ID 0-1" or "ID internal tx memory" has been
inserted in the transmitting unit, or this is a "BACK-UP
UNIT".
…the green [B] and red [A] LEDs
blink 3 times per second during
start up.
The “Key ID 0-1” is damaged or the “ID internal tx
memory” is damaged or not present.
... the green [B] and red [A] LEDs
blink alternately.
30 s left before the transmitting unit automatically switches
o󰘯.
The green LED [B] blinks and the
red LED [A] is steady during start
up.
The UNPAIR procedure has been performed.
See paragraph 6.3 to check the meaning of LEDs for Data Feedback function [C].