Instruction Manual

LIUDPP002_eng-00 AUTEC
56
When carrying out maintenance on the Machine, always disconnect power
supply from the Receiving Unit. In the event of necessary maintenance on the
Machine (by way of example: welding), disconnect all the electrical connections
of the Receiving Unit.
9.2.1 Daily routine maintenance
Before 󰘵arting to work:
- Make sure that the symbols on panel on the Transmitting Unit and on the Receiving Unit are
clearly visible and replace the panel if necessary.
- Make sure that the plates on the Transmitting Unit and on the Receiving Unit are readable and
intact (refer to the speci󰘰c part in the Manual concerning the Transmitting Unit and the
Receiving Unit).
- Make sure that the mechanical operation of the GSS or EMS pushbutton is correct.
- Make sure that the Transmitting Unit and the Receiving Unit are undamaged in all their parts.
- Check the Receiving Unit 󰘵atus and remove any material from it (du󰘵, remnants, object, etc.):
never use solvents or 󰘱ammable/corrosive materials for cleaning, and do not use high-
pressure water cleaners or 󰘵eam cleaners.
- Check that the wiring of the Receiving Unit is intact and connected.
During normal operation:
- Do not damage the Transmitting Unit (avoid falls, bumps, contact with water, 󰘱uids or liquids,
etc.).
- Pay attention not to let materials (by way of example: concrete, sand, grease, dirt, lime, du󰘵,
etc.) deposit on the Transmitting Unit because they can compromise its use and safety.
After using the Radio Remote Control:
- Clean the Transmitting Unit: never use solvents or 󰘱ammable/corrosive materials and do not
use water jet cleaners, or air pressure or 󰘵eam pressure cleaners.
- Store the Transmitting Unit in clean and dry places.
9.2.2 Three-month routine maintenance
At lea󰘵 every three months:
- Check the correct correspondence between the commands that are sent and the manoeuvres
that are carried out by the Machine.
- Make sure that the SAFETY outputs (of UMFS function) only activate after the Radio Remote
Control has 󰘵arted, and when at lea󰘵 one movement command is sent to the Machine. Also
make sure that the SAFETY outputs disable when all the movement commands are released.
This is safety critical maintenance: it is necessary to keep a record (date, signature, comments)
showing that this check has been regularly carried out. Keep the record together with other
in󰘵allation documents.
- Make sure that all the outputs in the Receiving Unit operate correctly, and check that each
output activates when the corresponding operation is enabled and deactivates when the
operation is disabled.