8.3 Operational use
The use of Radio Remote Controls is 󰘵rictly limited to properly trained Personnel.
All instructions for correct use are given in "Part C" of the Manual (related to the Transmitting
Unit).
When the Radio Remote Control is in󰄋alled on Machines on board vehicles,
switch off the Receiving Unit while the vehicle is travelling.
Environmental working conditions are given in the following table.
Temperature Relative Humidity Air pressure
Transmitting Unit usage
from -25 to +55°C
(from -13 to +130°F)
from 5 to 95% from 70 to 106kPa
Receiving Unit usage
from -25 to +70°C
(from -13 to +158°F)
from 5 to 95% from 70 to 106kPa
In the previous table:
- Temperature of the Transmitting Unit refers to Class 5K4H of the 󰘵andard EN 50178.
- Temperature, relative humidity and air pressure during of the Receiving Unit refer to Class 5K2
of 󰘵andard EN 50178.
- The Receiving Unit can work at 70°C (185°F) only if the sum of currents corresponding to the
loads simultaneously activated by digital and analogue outputs does not exceed 10A.