4.5 Technical data
Performance of the automatic 󰘵op function (ATS)
SIL 3 / PL e ; cat.4 (4-wire wiring)
SIL 2 / PL d ; cat.3 (2-wire wiring)
Performance of the General Safe Stop (GSS)
function
SIL 3 / PL e ; cat.4 (4-wire wiring)
SIL 2 / PL d ; cat.3 (2-wire wiring)
Performance of the Emergency Stop (EMS)
function
SIL 3 / PL e ; cat.4 (4-wire wiring)
SIL 2 / PL d ; cat.3 (2-wire wiring)
Performance of the UMFS function SIL 2 / PL d ; cat.3
Cut in time of the automatic 󰘵op function (ATS) 0.5s
Cut in time of the manual active 󰘵op function (GSS
or EMS)
<160ms
Cut in time of the manual passive 󰘵op function
(GSS or EMS)
0.5s
Hamming di󰘵ance ≥15
Probability of undetected error
<10
-15
(Typical) working range 100m (330ft)
Command response time 80-130ms
The technical data related to the single Units belonging to the Dynamic+P series are provided
in the speci󰘰c parts of the Manual and in their Technical Data Sheets.
4.6 Identifying the Radio Remote Control
A serial number (S/N) univocally identifies each Radio Remote Control.
The serial number is provided in the identification plate on each Radio Remote Control Unit.
This is the only reference to be used for maintenance operations and for any other situation
when you need to precisely identify the Radio Remote Control.
The serial number mu󰘵 be mentioned in any communication with Autec, its dealers, In󰘵allers,
Maintenance Technicians of the Radio Remote Control and with the people who, in any capacity,
need information, spare parts or technical data concerning the Radio Remote Control.
Plates mu󰘵 not be removed from their position: removal immediately voids the
warranty.
Plates mu󰘵 not be altered or damaged, contact Autec for replacement.