Instruction Manual

LIUDPP002_eng-00 AUTEC
28
4.3.3 Automatic 󰄋op function (ATS)
The automatic 󰘵op function (ATS) prevents hazardous operation of the radio remote controlled
Machine and brings it to a safe 󰘵ate. This function is activated automatically:
- By the Receiving Unit due to passive 󰘵op, when the Receiving Unit does not receive correct
messages in a given time span (see paragraph 4.1).
- When a Radio Remote Control malfunction is detected.
INCORRECT
messages for a
given time span
Radio Remote
Control
malfunction
detected by the
Transmitting Unit
Radio Remote
Control
malfunction
detected by the
Receiving Unit
Switching o󰓐 the
Transmitting Unit
Passive 󰄋op
Deactivating the Receiving Unit's STOP outputs