The Radio Remote Control's op function can be considered EMS only if:
- It belongs to a Machine's emergency op function compliant with the
requirements of the Machinery Directive 2006/42/EC and of the ISO 13850
andard
- It belongs to a Machine's emergency op function that is always available
and operational, independently from the Machine's working mode
- The Transmitting Unit is the only control ation of the Machine. If, on the
other hand, there is another non-remote control ation, the EMS function
present in the Radio Remote Control mu always be made available and
operational.
The red pushbutton on the Transmitting Unit mu not be the only means to
initiate the emergency op function in the radio remote controlled Machine.
Never leave the Transmitting Unit unguarded to avoid uncertainty about the
availability or unavailability of the EMS function.
The “mission time” of the EMS function, as defined in international andards
and requirements, is 20 years. In any case, the Radio Remote Control mu
be replaced within this period. The "mission time" mu not be considered as
a warranty period.
After the activation of the red pushbutton on the Transmitting Unit, the Machine
is not controlled by the Radio Remote Control any more. Any possible risks
that may arise from the activation of the op function mu be taken into
account by the Inaller of the Radio Remote Control, and by the Manufacturer
and the Owner of the Machine where the Radio Remote Control is inalled.
The Radio Remote Control User mu be properly trained about this.