Instruction Manual
8.9.1 Monitored commands
When the START pushbutton is pressed during the Radio Remote Control start up, the
Transmitting Unit monitors the status of commands D2-D20, A1-A8, H1-H8 and L1-L8 and
signals if any command is active through the LEDs. In this case, the Transmitting Unit
automatically switches o when the signal ends. If none of the monitored commands is active,
the Radio Remote Control starts.
Commands monitored by the Transmitting Unit during start up are chosen
by the Machine Manufacturer according to the risk assessment. If this
assessment was positive, the Manufacturer can ask Autec to modify the
behaviour of commands D2-D20, A1-A8, H1-H8 and L1-L8 during start up.
Look up for monitored and non-monitored commands in the Technical Data
Sheet.
Commands D21-D48 and A9-A12 are not monitored during start up.
When the START pushbutton is pressed to start the Radio Remote Control,
the commands that are not monitored during start up, if active, immediately
activate the Machine functions that are associated with them.
AUTEC - Dynamic Series
General operating instructions 25
LIUFJC000_eng-00