Instruction Manual

6.4.5 At the end of installation
Make sure that during installation the protection measures on the Radio
Remote Control and/or in the Machine have not been made ine󰓐ective by
improper installation works.
Look up in the Technical Data Sheet and check that the frequency band set
in the Radio Remote Control is permitted in the country of use.
6.4.6 Testing
The Installer must check and 󰘰ll in the Technical Data Sheet in all its parts, adding
the date in which the radio remote controlled Machine has been put into service,
their stamp and signature.
After installing and wiring the Receiving Unit, test the Machine controlled
by the Radio Remote Control and verify that the operations carried out
correspond exactly to the commands sent, including in particular but not
limited to the functionality of the STOP command.
Make sure that the SAFETY outputs (of UMFS function) only activate after
the Radio Remote Control has started, and when at least one movement
command is sent to the Machine. Also make sure that the SAFETY outputs
disable when all the movement commands are released. The UMFS safety
function may be not available for the ARX and CRX receivers only (see
chapter "description" in "Part D" of the Instruction Manual).
In case of malfunction, disable the system “Machine+Radio Remote Control”
until the problem has been completely solved and the installation and
functionality is con󰄈rmed to be correct..
36
LIUDYN002_eng-01
Installation
AUTEC - Dynamic Series