6.4.2 Mounting and fastening the Receiving Unit in the best position
Place the Receiving Unit so as to avoid incidental contact.
Place the Receiving Unit so that it can be easily reached in case of need.
Place the Receiving Unit so that it can be easily reached, and far from heat
sources (i.e. exhaust pipes, heat exchangers, radiators).
Place the Receiving Unit vertically, with the cable gland or the plug facing
down.
NO NO YES
Fix the Receiving Unit in four points, using the speci󰄈c holes in the housing.
Do not perforate the Receiving Unit in any case.
When installing on Machines that are subject to intense mechanical stress
(by way of example: vibrations, rough paths, sudden movements), it is
recommended to 󰄈x the Receiving Unit to the Machine with the appropriate
vibration dampers.