Instruction Manual
LIUFJQ001_eng-00 AUTEC
26
8.12.1 Low battery
The Transmitting Unit indicates if the battery is not sufficiently charged (the red LED blinks and
an acouic signal sounds).
The Transmitting Unit automatically switches off after 3.5 minutes after the onset of the signal.
It is necessary to bring the Machine to a safe ate and replace the battery with a charged one
(see paragraph 8.7).
8.12.2 When the Transmitting Unit is not used
If the Transmitting Unit remains arted for a certain time while none of these commands are
enabled: SAFETY, D2-D10, H1-H8 or L1-L8, then it automatically switches off. This time frame
is specified in the Technical Data Sheet (Automatic Switch Off).
Setting or removal of the automatic switch off time (Automatic Switch Off) is done
by Autec and decided by the Machine Manufacturer, according to his risk assessment
and to the operation and functions he needs on the Machine.
8.12.3 Non-op use
The Transmitting Unit indicates if it has been on for eight hours non-op (the red LED blinks
and an acouic signal sounds).
The Transmitting Unit automatically switches off after 3.5 minutes after the onset of the signal.
Bring the Machine to a safe ate before the Transmitting Unit automatically switches off.
8.13 Switching o the Transmitting Unit
Switch off the Transmitting Unit when not actively using the Radio Remote
Control to operate the Machine, or when work is otherwise interrupted, even
for short periods. Do not leave the load hanging or the Machine in dangerous
conditions (even when charging the Unit or changing the battery).
FAILURE TO DO SO CAN RESULT IN SERIOUS BODILY INJURY OR DEATH
AND/OR PROPERTY DAMAGE.
Voluntary switch off of the Transmitting Unit occurs in the following cases.
- when the power keyswitch is turned anti-clockwise or removed.
- When the battery is removed (see paragraph 8.7.2).
- When the STOP pushbutton is pressed.