When a radio link is interrupted:
- all outputs in the Receiving Unit are disabled,
- it is not possible to enable or disable the Machine commands through the Transmitting
Unit until the Radio Remote Control is started up again.
Please note that when the START pushbutton is pressed to start up the Radio
Remote Control after the radio link had been interrupted, commands that
were enabled before the interruption, and the resulting Machine's functions,
are immediately activated.
The Machine's Manufacturer or those who integrate the Radio Remote Control
in the Machine must take this Radio Remote Control behaviour into account
when carrying out the risk assessment. The Machine Manufacturer or those
who integrate the Radio Remote Control on the Machine must inform the
User if they believe that the reactivation of such Machine functions may
entail hazardous situations that cannot be reduced by reasonable technical
measures implemented on the Machine itself. In this case the User must be
appropriately trained to follow the procedure provided in paragraph "Radio
link interruption" in "Part C" of the Manual.