Warnings for installation
General
26
9 Warnings for installation
Besides instructions established by the machine's manufacturers, installers must
always observe the following warnings.
9.1 General
Respect and enforce the provisions of all reference standards relevant in the con-
cerned application field (i.e. IEC 60204-32 for hoisting machines).
Always follow the instructions provided in the “technical data sheet” to carry out
correct installation.
9.2 Mounting and fastening the receiving unit in the best position
Place the receiving unit so that it can be easily reached in case of need.
Place the receiving unit so that it can be easily reached, and far from heat sources
(i.e. exhaust pipes, heat exchangers, radiators).
Place the receiving unit vertically, with the plug facing down.
The receiving unit's back should be placed against a metal surface, to improve
heat sink effect.
Fix the receiving unit in four points, using the specific holes in the housing.
Do not perforate the receiving unit in any case.
It is recommended to use the appropriate vibration dampers when installing the
system on machines that produce strong vibrations.
9.3 Mounting and fastening the antenna in the best position
Install the antenna so that shields, structures or materials do not obstruct the ra-
dio link; in particular:
the antenna must be installed in a vertical position, and possibly near the work
area
the antenna must not be shielded by metal objects
The antenna must be placed at least 50 cm far from metal objects in its surround-
ings.
If these warnings are disregarded, the typical working range of the radio remote
control may be reduced.
9.4 Wiring
Make sure that the receiving unit's power supply is protected against short circuits
and is supplied either by a battery or by a power supply unit with safety isolating
transformer. Limits provided in the technical data must be observed.