User's Manual
18
LIUCRD000_eng-00
Light signals
AUTEC - Dynamic Plus series
7.4 RUN LED
The RUN LED indicates the status of the communication between the Receiving Unit and
the CAN network Master node.
Signal Meaning
The RUN LED is o.
The Receiving Unit does not work as a CAN network
node.
The RUN LED blinks.
The Receiving Unit does not send commands in the CAN
network.
The RUN LED is on.
The Receiving Unit is working correctly as a node in the
CAN network.
RUN LED signals reect the guidelines of the CANopen® standard, CiA recommendation 303-3.
7.5 ERR LED
The ERR LED indicates the status of the CAN communication.
Signal Meaning
The ERR LED is o. The CAN communication is working correctly.
The ERR LED blinks. The CAN communication does not work correctly.
The ERR LED is on. No CAN communication.
ERR LED signals reect the guidelines of the CANopen® standard, CiA recommendation 303-3.
7.6 SETUP LED
The SETUP LED shows the memory card and the address key status.
Signal Meaning
The SETUP LED is o. No errors in the memory card or in the address key.
The SETUP LED blinks once. Error on the address key.
The SETUP LED blinks twice. Error on the memory card.