REMOTE SETUP procedure
D - 8
If the proportional outputs are activated by actuators that are not joysticks (i.e. po-
tentiometer, switch), calibrate maximum and minimum values according to the
abovementioned procedure.
If a speed selector is present on the transmitting unit, minimum and maximum
values have to be calibrated for each of the selector positions.
If inputs are used in the receiving unit to select different speeds, calibration must
be performed while these inputs are active.
6.2 Calibrating values related to the rest position of proportional
outputs (offset)
1. Start up the radio remote control.
2. Press the TEACH pushbutton in the receiving unit and do not release it until
the SETUP LED illuminates.
3. Enable and release the “TEACH +” of the corresponding switch on the trans-
mitting unit and press and release the START pushbutton soon after.
4. Repeat actions described in point 3 until the SETUP LED on the receiving unit
starts blinking three times.
5. Set the desired values as follows:
- Move the joystick out of the rest position of the axis to be calibrated. Main-
tain the position and use the TEACH selector on the transmitting unit to set
the desired value.
- Press the STOP pushbutton to save the calibration. All calibrations are
saved in the data memory.
- To set other values, unlock the STOP pushbutton, press the START push-
button and repeat actions described in point 5.
6. To leave the procedure, press the TEACH pushbutton on the receiving unit
and do not release it until the SETUP LED switches off.
If the proportional outputs are activated by actuators that are not joysticks (i.e. po-
tentiometer, switch), calibrate values related to the rest position according to the
abovementioned procedure.