User's Manual
Table Of Contents
REMOTE SETUP procedure
AUTEC Dynamic Series
LIARSE00-01.fm Part D: ARS receiving unit
D - 7
ENG
6 REMOTE SETUP procedure
Proportional outputs in the ARS receiving unit are factory set: values are given in
the technical data sheet.
The REMOTE SETUP procedures is used to modify:
- maximum and minimum values of proportional outputs (see paragraph 6.1),
- values related to the rest position of proportional outputs (offset) (see
paragraph 6.2),
- direction of movements of joystick's axis (see paragraph 6.3).
It is also possible to restore factory settings of proportional outputs (see
paragraph 6.4).
The REMOTE SETUP procedure can only be performed by skilled and prop-
erly trained personnel.
During the REMOTE SETUP procedure, pay particular attention to the ma-
chine behaviour, as it moves as a response to acting on the actuators.
It is possible to restore factory settings at any time, if necessary (see
paragraph 6.4).
6.1 Calibrating maximum and minimum values of proportional out-
puts
1. Start up the radio remote control.
2. Press the TEACH pushbutton in the receiving unit and do not release it until
the SETUP LED illuminates.
3. Set the desired values as follows:
- To set the maximum value, move the joystick to the maximum range of the
semi-axis to be calibrated. Maintain the position and use the TEACH selec-
tor on the transmitting unit to set the desired value.
- To set the minimum value, move the joystick slightly out of the rest position
of the semi-axis to be calibrated. Maintain the position and use the TEACH
selector on the transmitting unit to set the desired value.
- After calibrating one joystick, press the STOP pushbutton to save calibra-
tions. All calibrations are saved in the data memory.
- To set other values, unlock the STOP pushbutton, press the START push-
button and repeat actions described in point 3.
4. To leave the procedure, press the TEACH pushbutton on the receiving unit
and do not release it until the SETUP LED switches off.