If the proportional outputs are activated by actuators that are not joysticks (i.e. po-
tentiometer, switch), calibrate maximum and minimum values according to the
abovementioned procedure.
If a speed selector is present on the transmitting unit, minimum and maximum
values have to be calibrated for each of the selector positions.
If inputs are used in the receiving unit to select different speeds, calibration must
be performed while these inputs are active.
6.2 Calibrating values related to the rest position of proportional
outputs (offset)
1. Start up the radio remote control.
2. Press the TEACH pushbutton in the receiving unit and do not release it until
the SETUP LED illuminates.
3. Activate and release the “TEACH +” command related to the corresponding
switch on the transmitting unit.
4. Press and release the START pushbutton.
5. Repeat actions described in points 3. and 4. until the SETUP LED on the re-
ceiving unit starts blinking three times.
6. Set the desired values as follows:
- Move the joystick out of the rest position of the axis to be calibrated. Main-
tain the position and use the TEACH selector on the transmitting unit to set
the desired value.
- After calibrating one joystick, press the STOP pushbutton to save calibra-
tions. Calibrations are saved in the data memory on the DTK connector.
- To set other values, unlock the STOP pushbutton, press the START push-
button and repeat actions described in point 6..
7. To leave the procedure, press the TEACH pushbutton on the receiving unit
and do not release it until the SETUP LED switches off.
If the proportional outputs are activated by actuators that are not joysticks (i.e. po-
tentiometer, switch), calibrate values related to the rest position according to the
abovementioned procedure.