Users Manual

Never leave the Transmitting Unit unguarded in order to avoid uncertainty
about the availability or unavailability of the stop function.
The “life time”, as de󰄈ned in international standards and requirements, of
the stop function is 20 years. In any case, the Radio Remote Control must
be replaced within this period. The “life time” must not be considered as
a warranty period.
After the activation of the STOP on the Transmitting Unit, the Machine is not
controlled by the Radio Remote Control any more. Any possible risks that
may arise from the activation of the stop function must be taken into account
by the Installer of the Radio Remote Control, and by the Manufacturer and
the Owner of the Machine where the Radio Remote Control is installed.The
Radio Remote Control User must be properly trained about this.
InsomeRadioRemoteControls,thestopfunctionmaybeappointedtoaspeci󰘰c
actuator,suppliedondemand(“Enabling&Stop”pushbutton).Theinstructions
forthisactuator,ifpresent,areprovidedin“PartC”oftheInstructionManual.
4.3 Technical data
Command response time (typical) .............................................................................140ms
Stop time (typical) ................................................................................................... 100ms
Max.stoptime ............................................................................................................. 0.5s
Performance Level of the "stop protection" in compliance with ISO 13849-1 .............. PL d
The technical data related to the single Units belonging to the Air series are provided in the
speci󰘰cpartsoftheManualandintheirTechnicalDataSheet.
AUTEC - AIR SERIES
Radio Remote Control features 21
LIUAIR003_eng-01