User's Manual

5.2 ALARM LED (red)
The ALARM LED warns about anomalies in the receiving unit.
The ALARM LED... Meaning
…is o󰓐 The receiving unit works correctly.
... blinks once Error on the STOP outputs.
... blinks twice Error on the SAFETY outputs.
... blinks three times
Error on the outputs corresponding to direction
commands.
... blinks four times Error on the Take Control selector.
... is on The receiving unit does not work correctly.
5.3 STATUS LED (blue)
The STATUS LED warns about anomalies on the outputs or on the power supply and indicates
the reception of data from the transmitting unit.
The STATUS LED... Meaning
…is o󰓐 No radio link.
... blinks slowly Over-voltage on power supply.
... blinks fast The receiving unit receives data from the transmitting unit.
... is on Over-current in one of the PWM analogue outputs.
5.4 RUN LED (green)
The RUN LED indicates the status of the communication between the receiving unit and the
CAN network Master node.
The RUN LED... Meaning
…is o󰓐 The receiving unit does not work as a CAN network node.
… blinks
The receiving unit does not send commands in the CAN
network.
...is on
The receiving unit is working correctly as a node in the
CAN network.
RUN LED signals re󰘱ect the guidelines of the CANopen® standard, CiA recommendation 303-3.
6
LIADDE00-00
Plates
AUTEC - Dynamic Series