User's Manual
2 Technical data
Power supply ........................................................................................................ 8-30V
Antenna .............................................................................................................. dedicated
Rated current of outputs STP_1 and STP_2 ................................................. 7.5A (30V )
Rated current of output SAF_1 ..................................................................... 7.5A (30V )
Rated current of output SAF_2 ........................................................................ 3A (30V )
Rated current of digital outputs ........................................................................ 4A (30V )
Rated current of analogue outputs (PWM) ....................................................... 2A (30V )
Rated current of analogue outputs (voltage) ............................................... 10mA (28V )
Protection of SAF_2 (fuse F1) .......................................................... 3A (32V , autofuse)
Protection of power supply (fuse F2) ............................................. 7.5A (32V , autofuse)
Protection of STP_1 (fuse F3) ....................................................... 7.5A (32V , autofuse)
Protection of STP_2 (fuse F4) ....................................................... 7.5A (32V , autofuse)
Protection of SAF_1 (fuse F5) ....................................................... 7.5A (32V , autofuse)
Housing material .......................................................................................... PA6 (20% fg)
Protection degree ....................................................................................... IP65 (NEMA 4)
Dimensions .................................................................. 250x290x110mm (9.8x11.4x4.3In)
Weight ........................................................................................................... 3.8kg (8.4Lb)
3 Technical data sheet
The technical data sheet contains the wiring diagram showing the connection between the
receiving unit and the machine. It also contains the transmitting unit conguration and shows
the matching between commands sent and machine functions/movements.
Each technical data sheet must be lled in, checked and signed by the installer, who is
responsible for a correct wiring.
A copy of the technical data sheet must always be kept together with this manual (always
keep a copy of this data sheet for administrative purposes).
The wiring of the receiving unit outputs must always reect the wiring
indicated in the technical data sheet.