User's Manual

2 Technical data
Power supply ........................................................................................................ 8-30V
Antenna .............................................................................................................. dedicated
Rated current of outputs STP_1 and STP_2 ................................................. 7.5A (30V )
Rated current of output SAF_1 ..................................................................... 7.5A (30V )
Rated current of output SAF_2 ........................................................................ 3A (30V )
Rated current of digital outputs ........................................................................ 4A (30V )
Rated current of analogue outputs (PWM) ....................................................... 2A (30V )
Rated current of analogue outputs (voltage) ............................................... 10mA (28V )
Protection of SAF_2 (fuse F1) .......................................................... 3A (32V , autofuse)
Protection of power supply (fuse F2) ............................................. 7.5A (32V , autofuse)
Protection of STP_1 (fuse F3) ....................................................... 7.5A (32V , autofuse)
Protection of STP_2 (fuse F4) ....................................................... 7.5A (32V , autofuse)
Protection of SAF_1 (fuse F5) ....................................................... 7.5A (32V , autofuse)
Housing material .......................................................................................... PA6 (20% fg)
Protection degree ....................................................................................... IP65 (NEMA 4)
Dimensions .................................................................. 250x290x110mm (9.8x11.4x4.3In)
Weight ........................................................................................................... 3.8kg (8.4Lb)
3 Technical data sheet
The technical data sheet contains the wiring diagram showing the connection between the
receiving unit and the machine. It also contains the transmitting unit con󰘰guration and shows
the matching between commands sent and machine functions/movements.
Each technical data sheet must be 󰘰lled in, checked and signed by the installer, who is
responsible for a correct wiring.
A copy of the technical data sheet must always be kept together with this manual (always
keep a copy of this data sheet for administrative purposes).
The wiring of the receiving unit outputs must always re󰄉ect the wiring
indicated in the technical data sheet.
4
LIADDE00-00
Technical data
AUTEC - Dynamic Series