User's Manual
Signals Possible reason Solutions
The STATUS LED blinks
slowly.
Over-voltage on power
supply.
Make sure that the receiving unit power
supply is within the voltage limits
provided in the technical data.
The STATUS LED blinks
fast and irregularly.
The receiving unit loses
some data sent by the
transmitting unit.
Bring the transmitting unit close to the
receiving unit.
If this signal persists, contact the support
service of the machine manufacturer.
The STATUS LED is on.
Over-current in one of the
PWM analogue outputs.
Contact the support service of the
machine manufacturer.
The RUN LED blinks.
The receiving unit does
not send commands in
the CAN network.
Contact the support service of the
machine manufacturer.
The ERR LED blinks.
CAN communication
error.
Contact the support service of the
machine manufacturer.
The SETUP LED blinks
once.
Error on the address key.
Contact the support service of the
machine manufacturer.
The SETUP LED blinks
twice.
Error on the memory
board.
Replace the memory board in the DTK
connector with the spare memory, that is
provided on the inside of the cover (see
chapter 7).
The SETUP LED blinks
slowly.
A memory board is
connected to the BKK
connector.
If you are not copying the memory
board, remove the memory from the
BKK connector (see chapter 7).
The OP LED is on.
No radio link is available
with the Operator
transmitting unit.
Bring the transmitting unit close to the
receiving unit and press the START
pushbutton.
The SU LED is on.
No radio link is available
with the Supervisor
transmitting unit.
Bring the transmitting unit close to the
receiving unit and press the START
pushbutton.
14
LIADDE00-00
Malfunction signalled by the receiving unit
AUTEC - Dynamic Series