User Guide

G1 6 english
Heating in between seasons
Heating the stove in between seasons, when the
outside temperatures are higher, the flue gases may
not be able to escape completely and this may lead to
disturbances in the chimney draught, especially if the
temperatures are rising suddenly. The stove has to
be charged with less wood and the primary air has to
be increased so that the wood can burn down faster
(with visible flames) and thus the chimney flue can
stabilize.
Chimney fire
A Chimney fire may occur, due to sooting and
deposits in the chimney, if wrong or humid fuel is
used. Close all air inlets on the fireplace/chimney
immediately and call the fire brigade. Please have an
expert inspect your chimney for cracks and air-
tightness after the burning out of the chimney.
4. THE MOST IMPORTANT SPARES—OVERVIEW
Gaskets
Description Nr. drawing Part number
Flat gasket 8 x 2 x 400 mm 21 710096
Flat gasket 8 x 2 x 81 mm 23 710096
Round gasket d= 10 x 1100 mm 20 710319
Keramott
Description Nr. drawing Part number
G1 keramott base 3 716213
G1 keramott wood retainer 9 716249
G1 keramott lateral front left 8 716215
G1 keramott lateral rear left 7 716211
G1 keramott rear 4 716214
G1 keramott lateral front right 6 716247
G1 keramott lateral rear right 5 716248
G1 baffle plate 1 716054
G1 vermiculite baffle plate 2 716210
Other parts
Description Nr. drawing Part number
G1 door glass 22 716063
Stove lacquer -- 650002
Igniter -- 640162
Glass cleaner ½ litre -- 640070
Accessories
You can obtain floor plates made of glass or steel, hearth accessories or care products from your certified
dealer.
IMPORTANT: Have defective parts replaced by your certified dealer only. This will guarantee that your
stove functions properly and safely.
The fireplace must not be amended.
Maintenance
To clean the glass, please use a specialized product such as Thermohit glass cleaner. Lacquered
surfaces are to be cleaned only with a cloth (may be damp). Special cleaning agents should also be used
for stainless steel surfaces.
Cleaning
The stove, flue outlets and smoke pipes should be cleaned and inspected for deposits every year – if
necessary more often, e.g. after the cleaning of the chimney. The chimney also has to be cleaned
regularly by the chimneysweeper. Your chimneysweeper will inform you of the necessary inspection
intervals. An expert should inspect the stove annually.
Keramott numbering = order of installation