Install guide
ARMY TM 5-6675-308-34
MARINE CORPS TM 08837A-34/2
Table 3-4.
Troubleshooting
with
Bit
Malfunction
Words
–
Continued
Digit Value
Malfunction
Probable
cause/troubleshooting
Reference
e.
If
a
malfunction indicator
lights
again,
record
which
one
lights
and
record
the
nonzero
contents
of
monitor
ID
1
or
2.
f.
If
the malfunction
does
not
clear,
turn
system
off
and
realign.
g.
If
the malfunction
does
not repeat, continue with the test.
h.
If
the malfunction
still
exists,
perform
the
following
steps
as
applicable.
The
malfunction
word
structure
is
ID
MAL
ABCDEF
where:
ID
represents
the
ID
number of the particular malfunction word.
ABCDEF
represents the
6
digits
in
the malfunction
word.
The
numerical
value
of
a
digit
designates
a
particular malfunction.
The
table identifies the malfunction
and
gives
the probable
cause
and
additional troubleshooting instructions.
Example:
02
MAL
000006
means
digit
F
of
ID
2
malfunction
word
has
a
value
of
6.
This
indicates two malfunctions: Time-out counter inoperative;
and
time-out counter interrupt
invalid.
ID
1
MAL
A
Not
used
B
1JJ,4$,6
Checksum
error
or
7
c
lor3
Discrete
party
fail
2or3
0p
code
test
fail
4,5,6, or
7
Memory
test
fail
Replace
memory
Al
and
IMU,
computer
Para
3-13b
and
computer
power
supply Para
3-15c
Para
3-15b
Para
3-13c
Replace
computer
discrete
1/0
A9
Para
3-15a
Replace
computer control
no.
1
card
A3
Para 3-15a
a)
Reseat
computer memory
Al,
and
tighten para 3-15b
memory wedge
locks
b)
Replace
computer,
keeping
old
memory
A
1
Para 3-15b
and
IMU
c)
Replace
memory
A
1
and
IMU
Para
3-13c
D1
Platform 1/0 short
loop
fail
Replace
computer platform 1/0
card
A8
Para
3-15a
2
Computer
serial
data
bus
Replace computer 1/0 controller card
A7
Para 3-15a
fail
4
E4
A/D
ShOXt
100P
fail
CDU
serial
data
bus
Replace
computer
A/D
card
Al
1
Refer to
ID
5
MAL
Para 3-15a
F
Not
used
Change 6
3-17