Install guide

ARMY TM 5-6675-308-34
MARINE CORPS TM 08837A-34/2
Table 3-3.
Direct
Support
Troubleshooting-Continued
Malfunction
Probable
cause
Troubleshooting/correc
tive
action
b.
Defective
cable
W5
c.
Defective
PS
7.
PADS
shuts
down
with
PS
Defective
PS
FAIL
fault indicator
DS2
white
8.
PADS
shuts
down
with
com-
a.
Computer overtemperature
puter fault indicator white
shut
down
b.
Defective
computer
thermostat
c.
Defective
computer
power
supply
d.
Defective
computer
9.
PADS
on
but
all
CDU
lights
a.
Intensity
set
dim
are
dark
(fan(s)
operate)
b.
Defective
cable
W
1
c.
Defective
computer
supply
d.
Defective
CDU
e. Defective
computer
c.
If both
voltages
are
between
105
and
125
VAC,
replace
fan.
Refer
to
TM
5-6675-308-12
and/or
TM
08837A-12/l
See
step
5b
above
See
step
5C
above
Replace
PS.
Refer
to
para
3-13d
Allow
system
to
cool
down.
If
system
oper-
ates
for
a
short period,
check
operation of
computer
fan.
Refer to
steps
5
and
6.
Repair
as
necessary
Measure
resistance
across
computer
thermo-
static
switch
S
1
(Refer to para 3-15c to
separate
computer
power
from
computer
sub-
assembly
to
gain
access
to
switch
S
1
(30,
figure
3-7).
If
less
than 300
ohms,
disconnect
one
lead
from
switch
S
1.
If
resistance
is
still
less
than 300
ohms,
replace
computer
Replace
computer power
supply.
Refer to
para
3-15c
Replace
the circuit
cards
below,
listed
in
order
of
probable
malfunction.
Refer
to
para
3-15a
(1)
1/0
Discrete
card
A9
(2)
Data
buffer
card
A6
(3)
Computer
(4)
Memory
module Al
and
IMU
Perform
lamp
test. Refer to
para
3-4
Check
WI. Refer to para
3-7.
Replace
as
necessary
If
fault indicators
do
not
set
white
and
then
reset
black
during
lamp
test,
replace
compu-
ter
power
supply.
Refer to para
3-15c
Replace
CDU.
Refer to para
3-13a
Replace
computer. Refer to para
3-13b
3-14