Install guide
figure 3-1
ARMY TM 5-6675-308-34
MARINE CORPS TM 08837A-34/2
Table 4-18.1. Operational Program Loading Using Tape Reader, Part No. 877406-2 – Continued
Malfunction
Test procedure
Normal indication
indication/corrective action
av. Turn on PADS via CDU and
advance to monitor mode
NOTE
Zeros may be entered for values of
survey parameters.
aw. After elevation is entered press
MON, ID, 1,
4, ENT pushbut-
tons
ax. Compare CDU checksum read-
out to the program checksum
written on front of the opera-
tional program tape
Data display shows:
14 MCS XXXXX (checksum)
Checksums are equal
Checksums are not the same: Reload
operational program
NOTE
Loading of the operational program is complete and has been verified. The equipment can be reconfigured as
required . If an IMU has just been recalibrate the memory unit normally is removed from the computer and stored
with the IMU in an IMU transit case.