Install guide

ARMY TM 5-6675-308-34
MARINE CORPS TM 08837A-34/2
Table 4-16. Definitions of Teletypewriter Input Messages
Teletypewriter input message
Definition
TTY REQUEST:
DATA ENTRY :
LATITUDE
Latitude of the test site referenced to Clark 1866 spheroid. Degrees,
minutes, seconds (separated by a space) to nearest second. For
southern latitude, put a minus sign in front of degrees
ELEVATION
Elevation of this site in feet, referenced to Clark 1866 spheroid, to
nearest foot
DATE
4-digit Julian date
SER NO
IMU serial number found on unit nameplate
THEODOLITE READING
Horizontal angle measured from the azimuth mark to the porro prism
in a clockwise manner in Army roils to nearest 0.01 mil
Refer to Chapter 5 for correct reading procedure
TAZ
True azimuth of target in Army roils to nearest 0.01 mil
OPERATOR ENTRY :
DEFINITION :
IMU
Start IMU alignment
RDY
Acknowledges requested action
BYP
Bypass theodolite test
N1, N2 CAL
Print alignment data table
N1 is number of first parameter to be printed, N2 the last (e.g., 1200
CAL causes all data to print)
SER
Print serial number, data and IMU cal tape memory checksum number
STS
Print status
SUM
Print failure table summary
TST
Print list of completed tests
HLT
Stop table print
REP
Repeat present table