Install guide

ARMY TM 5-6675-308-34
MARINE CORPS TM 08837A-24/2
Table 4-7. Computer Testing and Troubleshooting
Malfunction
Teat procedure
Normal indication
indication/correctie action
1.
TEST SETUP
Check that the diagnostic align-
ment program is loaded into the
computer is memory and that the
computer is functional in accor-
.
dame with table 4-6, 4-6.1, 4-6.2,
or 4-63.
2. COMPUTER DIAGNOSTIC
TEST
NOTE
During this test, any failure message listed in table 4-10 maybe printed. Perform corrective action specified in table 4-10.
If a memory is replaced, operate and reload per tables 4-6 through 4-6.3 dependent upon memory and reader tapes. After
replacing any other card, repeat the diagnostic test from step 2a (table 4-7). If the checksum is incorrect, reload the
diagnostic-alignment program for core memory, or main program for solid state memory.
2a. Press
EXECUTE switch-in-
dicator go on to start diagnostic
program
2b. Type character set CMP (selects
computer automatic test mode)
2c. PADS teat set is now in the com-
puter automatic teat mode and
requires no operator control for
approximately 15 minutes
4-56
Change 6
EXECUTE switch-indicator lights
TTY printa out:
PADS DIAGNOSTIC ALIGNMENT
PROGRAM or PADS
SOLID STATE DIAGNOSTIC
ALIGNMENT PROGRAM
PRoGRAM CHECKSUM XXXXXX
SELECT TEST MODE
TTY prints out:
COMPUTER AUTOMATIC
TEST MODE
TTY prints out at leas than 8 minute
intervals
XXX TEST CYCLES PASS
Where XXX is a number of
through test program
passes
TTY prints out
XXX TEST FAIL
Refer to table 4-10 for corrective
action.
Type STS and refer to
table 4-9
NOTE
If TTY prints OUt: XXX TEST
FAIL press PADS ON/OFF switch-
indicator and ENTER switch. Wait
2 to 3 minutes then turn PADS on,
press EXECUTE switch-indicator,
and return to step 2a, table 4-7.