Install guide
ARMY TM 6-6675-308-34
MARINE CORPS TM 08837A-34/2
Table 4-6.3. Solid State Memory Loading Using Tape Reader, Part No. 877406 -2- Continued
Malfunction
Test procedure
Normal indication
indication/corrective action
2c. Set tape reader FAST/SLOW
switch to FAST
2d Press REVERSE switch-in-
dicator to on
2c. Press REVERSE switch-in-
dicator to off
NOTE
Tape will stop near the beginningof
the reel. Repeat steps 2d and 2e
until tape stops at end of readable
leader.
2f. Lift tape reader read head cover
and remove part 1 and load part
2 (of 3) of PADS solid state pro-
gram 868182-X on tape reader.
Gently lower read head cover.
2g. Set tape reader FAST/SLOW
switch to SLOW
2h. Press MEMORY LOAD switch-
indicator to on
2i. Press MEMORY LOAD switch-
indicator to off
2j. Set tape reader FAST/SLOW
switch to FAST
2k. Press REVERSE switch-indica-
2f.
2m.
2n.
2o.
2p.
2q.
tor to on
Press REVERSE switch-in-
dicator to off
Lift tape reader read head cover
and remove part 2 and load part
3 (of 3) of PADS solid state
program tape number 868182-X
on tape reader. Gently lower
read head cover
Set tape reader FAST/SLOW
switch to SLOW
Press MEMORY LOAD switch-
indicator to on
Press MEMORY LOAD switch-
indicator to off
Set tape reader FAST/SLOW
switch to FAST
4-54.16
Change 6
REVERSE switch-indicator lights. Tape
rewinds and stops at beginning of
reel
REVERSE switch-indicator goes off
No. 10 LED indicator lights steady
MEMORY LOAD switch-indicator
lights. Tape reader reads tape and
stops at end of reel
MEMORY LOAD switch-indicator
goes off
REVERSE switch-indicator lights.
Tape rewinds and stops at beginning
of reel
REVERSE switch-indicator goes off
No. 10 LED indicator lights steady
MEMORY LOAD switch-indicator
lights. Tape reader reads tape and
stops at end of reel
MEMORY LOAD switch-indicator
goes off