Install guide

ARMY TM 5-6675-308-34
MARINE CORPS TM 08837A-34/2
Table 4-6. Computer Diagnostic/Alignment Program - Continued
Malfunction
Test procedure
Normal indication
indication/corrective action
NOTE
Press MEMORY LOAD switch-indi-
cator off and back on if a stop code
is reached prior to tape data being
read.
3b. Press MEMORY LOAD switch-
indicator to off
3c. Press REVERSE switch-indica-
tor to ON
3d. Press REVERSE switch-indica-
tor to off
NOTE
Tape will stop near the beginning of
the reel. Repeat steps 3c and 3d
until tape stops at end of readable
leader.
3e. Set tape reader SPOOLING
3f.
3g.
3h.
3i.
switch to DISABLE
Remove part 1 and load part 2
(of 2) of PADS diagnostic align-
ment tape number 877418-5 on
tape reader
Set tape reader SPOOLING
switch to ENABLE
Press MEMORY LOAD switch-
indicator to on
Press MEMORY LOAD switch-
indicator to OFF
3j. Press EXECUTE switch-indica-
tor to on
NOTE
Ignore PARITY ERROR switch-indi-
cator light unless tape stops.
MEMORY LOAD switch-indicator
goes off
REVERSE switch-indicator lights.
Tape rewinds and stops at begin-
ning of reel
REVERSE switch-indicator goes off
MEMORY LOAD switch-indicator
lights. Tape reader reads next tape
section and stops at end of reel
MEMORY LOAD switch-indicator
goes off
EXECUTE switch-indicator lights
TTY prints out:
PADS DIAGNOSTIC
ALIGN-
MENT PROGRAM
PROGRAM CHECKSUM XXXXXX
SELECT TEST MODE
4-54
Change 1