Specifications

PAGE 6 AMIS MP8 INSTALLATION & OPERATION MANUAL
WIRING:
Connect the speaker output of the first amplifier to INPUT terminals
labelled AMP 1, maintaining correct polarity. Connect the speaker
load for this amplifier to OUTPUT terminals labelled ZONE 1.
Repeat for additional amplifiers and speaker loads.
Always use appropriate cable for amplifier to MP8 and MP8
to speaker wiring.
POWER REQUIREMENTS:
The MP8 can operate on the supplied plug pack and/or separate
24V DC power supply.
A NOTE ABOUT GROUNDING: It may be necessary
in some circumstances to ground the MP8 to
eliminate noise from the monitor speaker. This can
be done using the negative terminal of the 24VDC IN
binding post or by making sure that the chassis is
electrically connected to the equipment rack
(which should be grounded).
A NOTE ABOUT SPEAKER ISOLATION: When a
zone is selected for monitoring it is isolated from
the other amplifiers by 1kohm resistors. The negative
input is also AC referenced to chassis ground with
a capacitor.
INSTALLATION