Specifications

4. INSTALLATION
Wiring:
Connect the speaker output of the first amplifier to INPUT terminals labelled AMP 1,
maintaining correct polarity. Connect the speaker load for this amplifier to OUTPUT
terminals labelled ZONE 1.
Repeat for additional amplifiers and speaker loads.
Always use appropriate cable for amplifier to MP8 and MP8 to speaker wiring.
Power Requirements:
The MP8 can operate on the supplied plug pack and/or separate 24V DC power supply.
75.8mm [3.0"]
88.0mm [3.5"]
467.0mm [18.4"]
482.0mm [19.0"]
444.0mm [17.5"]
210.0mm [8.3"]
25.0mm [1.0"]20.0mm [0.8"]
MONITOR SPEAKER
VOLUME
PROGRAM
LEVEL
+3dB
0dB
- 3dB
- 6dB
- 9dB
-12dB
-18dB
-24dB
1 2
3
4
5
6
7
8
MP 8 Monitor Panel
POWER
ON
SIGNAL
PRESENT
AMPLIFIER
SELECT
AMPLIFIER 1
AMPLIFIER 2
AMPLIFIER 3
AMPLIFIER 4
AMPLIFIER 5
AMPLIFIER 6
AMPLIFIER 7
AMPLIFIER 8
INSTALLATION SERIES
Australian Monitor
AMP 1 AMP 5AMP 2 AMP 6AMP 3 AMP 7AMP 4 AMP 8
INPUT FROM 100V LINE AMP.
+ ++ ++ ++ +
ZONE 1 ZONE 5ZONE 2 ZONE 6ZONE 3 ZONE 7ZONE 4 ZONE 8
OUTPUT TO 100V SPEAKERS
+ ++ ++ ++ +
24 VDC IN
12-24V AC/DC
TIP +VE
+
ENGINEERED BY AUDIO TELEX COMMUNICATIONS PTY LTD SYDNEY AUSTRALIA
A NOTE ABOUT GROUNDING:
It may be necessary in some circumstances to ground the MP8 to eliminate noise
from the monitor speaker. This can be done using the negative terminal of the
24VDC IN binding post or by making sure that the chassis is electrically connected to
the equipment rack (which should be grounded).
A NOTE ABOUT SPEAKER ISOLATION:
When a zone is selected for monitoring it is isolated from the other amplifiers by
1kohm resistors. The negative input is also AC referenced to chassis ground with a
capacitor.
INSTALLATION SERIES
Australian Monitor
INSTALLATION SERIES
Australian Monitor
8 9
5. DIMENSIONS