Australian Monitor INSTALLATION SERIES Clever Features, Contractor Friendly MP8 8 Zone Monitor Panel INSTALLATION AND OPERATION MANUAL MP 8 Monitor Panel AMPLIFIER 1 ON AMPLIFIER 2 MONITOR SPEAKER VOLUME PROGRAM LEVEL SIGNAL PRESENT AMPLIFIER 3 POWER +3dB AMPLIFIER 4 0dB - 3dB - 6dB AMPLIFIER SELECT AMPLIFIER 5 - 9dB -12dB -18dB AMPLIFIER 6 1 2 3 4 5 6 7 8 AMPLIFIER 7 -24dB AMPLIFIER 8 Australian Monitor INSTALLATION SERIES
Issue Original Copyright 14th April 2003 Rev A 14th April 2003 AUS, EUR, USA This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK. DO NOT REMOVE COVER (OR BACK).
CONTENTS 1. Introduction Page 4 2. Front Panel 5 3. Back Panel 7 4. Installation 8 5. Dimensions 9 6. Operation 10 7. Block Diagram 11 8.
1. INTRODUCTION The Australian Monitor Installation Series MP8 is a 2 RU monitoring panel that allows you to monitor any of up to 8, constant voltage or low impedance speaker lines. This can be done via the on-board 2.5" monitor speaker or via the 8 segment VU meter. The MP8 also provides signal present LED’s for each amplifier as well as LED’s to indicate which amplifier is currently selected for monitoring. The MP8 operates from either an AC/DC 12V-24V plug pack or via 24 VDC & boasts ample label space.
6 5 8 MP 8 Monitor Panel AMPLIFIER 1 ON AMPLIFIER 2 MONITOR SPEAKER VOLUME PROGRAM LEVEL SIGNAL PRESENT AMPLIFIER 3 POWER +3dB AMPLIFIER 4 0dB - 3dB - 6dB AMPLIFIER SELECT AMPLIFIER 5 - 9dB -12dB -18dB AMPLIFIER 6 1 2 3 4 5 6 7 8 AMPLIFIER 7 -24dB AMPLIFIER 8 Australian Monitor INSTALLATION SERIES 1 2 4 3 7 9 2. FRONT PANEL ¬ Monitor Speaker: A 2.5” speaker is located behind a cloth grille. No cleaning is required.
² Labels: This area is available to custom label the zones each amplifier is driving. ³ Power On LED: This indicates there is power to the unit. NOTE: When using 24VDC IN terminals the power LED will always be on. ´ Power Switch: This switch switches power from the AC/DC plug pack input. NOTE: When using 24VDC IN terminals the unit is on regardless of switch position.
3 INPUT FROM 100V LINE AMP. AMP 1 AMP 2 + 12-24V AC/DC + AMP 3 + AMP 4 + AMP 5 + AMP 6 + AMP 7 + AMP 8 + + 24 VDC IN OUTPUT TO 100V SPEAKERS TIP +VE ZONE 1 ZONE 2 + + ZONE 3 + ZONE 4 + ZONE 5 + ZONE 6 + ZONE 7 + ZONE 8 + ENGINEERED BY AUDIO TELEX COMMUNICATIONS PTY LTD SYDNEY AUSTRALIA 1 2 4 3. BACK PANEL 12-24V AC/DC TIP +VE ¬ Power Socket: This 2.1mm socket accepts AC or DC voltage between 12V and 24V. For DC, tip is positive.
4. INSTALLATION Wiring: Connect the speaker output of the first amplifier to INPUT terminals labelled AMP 1, maintaining correct polarity. Connect the speaker load for this amplifier to OUTPUT terminals labelled ZONE 1. Repeat for additional amplifiers and speaker loads. Always use appropriate cable for amplifier to MP8 and MP8 to speaker wiring. Power Requirements: The MP8 can operate on the supplied plug pack and/or separate 24V DC power supply.
5. DIMENSIONS 444.0mm [17.5"] INPUT FROM 100V LINE AMP. AMP 1 AMP 2 + 12-24V AC/DC + AMP 3 + AMP 4 + AMP 5 + AMP 6 + AMP 7 + AMP 8 + + 24 VDC IN OUTPUT TO 100V SPEAKERS TIP +VE ZONE 1 ZONE 2 + ZONE 3 + ZONE 4 + ZONE 5 + + ZONE 6 + ZONE 7 ZONE 8 + + ENGINEERED BY AUDIO TELEX COMMUNICATIONS PTY LTD SYDNEY AUSTRALIA 482.0mm [19.0"] 467.0mm [18.
6. OPERATION The SIGNAL PRESENT LED’s give a continuous indication of the signal from each of the eight connected amplifiers. Note that very low levels may not be detected. To monitor a particular amplifier, SELECT the desired amplifier. The listening level may be adjusted using the MONITOR SPEAKER VOLUME. The PROGRAM LEVEL meter gives accurate indication of signal from the selected amplifier.
7. BLOCK DIAGRAM 8.SPECIFICATIONS -Monitor Volume Levels: Input for Max speaker output (10% THD) Pot @ 1: -6dB (Ref 100V) Pot @ 5: -14dB Pot @ 10: -27dB -Dimensions: 88.0 x 482.0 x 210.0 (HxWxD) mm -Weight: Net 4.0kg Shipping 5.4kg -Crosstalk: -72dB @ 1kHz -53dB @ 10kHz -Power Input: 12-24V AC/DC 8VA max -Signal Present Threshold: -24dB (6.
www.australianmonitor.com.au Sydney (NSW & ACT Sales) Private Bag 149, Silverwater NSW 1811 149 Beaconsfield Street, Silverwater NSW 2128 Ph: (02) 9647 1411 Fax: (02) 9648 3698 E-mail: nsw@audiotelex.com.au Melbourne (Vic & Tas Sales) P.O. Box 131, Blackburn South VIC 3130 22/277 Middleborough Road, Box Hill VIC 3128 Ph: (03) 9890 7477 Fax: (03) 9890 7977 E-mail: vic@audiotelex.com.au Brisbane (Qld Sales) P.O.