INSTALLATION AND OPERATION MANUAL AMC+ SERIES MIXER AMPLIFIERS AMC+30 AMC+60 AMC+120 AMC+250
IMPORTANT SAFETY INFORMATION PRÉCAUTIONS DURANT UTILISATION 1. Read these instructions. 1. LISEZ ces instructions. 2. Keep these instructions. 2. Tenez ces instructions. 3. Heed all warnings. 3. Notez tous les avertissements. 4. Follow all instructions. 4. Suivez toutes les avertissements. 5. Do not use this apparatus near water. 5. N’utilisez pas ce produit près de l’eau (la piscine, la plage, le lac, etc.). 6. Clean only with dry cloth. 6. Nettoyez seulement avec une étoffe sèche.
INTRODUCTION AND CONTENTS AMC+ SERIES INTRODUCTION 3 The Australian Monitor AMC+ series of amplifiers takes the heritage and reliability of our famous AMIS series amplifiers and integrates these features into low cost amplifiers for applications where reliability is everything, but the more elaborate features of our AMIS series are not required.
FRONT PANEL 1 2 3 4 5 6 1 CH 1–4 These control the levels for each channel input. 2 Bass There is 12dB of cut and boost at 100Hz. 3 Treble There is 9dB of cut and boost at 10kHz. 4 Master This controls the overall mixed output level. 5 On This LED indicates the unit is powered “on”. 6 Power This switch switches power on or off the mains. The up position is on.
REAR PANEL 5 4 7 6 1 CH 1–4 Each channel input section has two inputs: XLR input – This is a balanced microphone input. It has an input sensitivity of 1mV. RCA input – This is an unbalanced line level input. It has an input sensitivity of 150mV. The two RCA sockets are summed to mono internally.
INSTALLATION Mounting When rack mounting, it is advisable to allow 1 rack space above and below the amplifier. When multiple amplifiers are mounted in a rack, exhaust fans should be used on the rack. Airflow for cooling the AMC30, AMC60 and AMC120 is by convection from bottom to top. Airflow for cooling the AMC250 is by fan from front to side. Output Distance Wire Size + 100V 70V 4 ohm Direct Output The output terminal strip accepts wire sizes from 16-22AWG (1.5mm2 – 0.35mm2) or spade lugs.
TROUBLESHOOTING AND BLOCK DIAGRAM Troubleshooting Guide Trouble Likely Cause Remedy Power LED not on Power not reaching amplifier Check power switch is on Check mains connection Check mains fuse Distorted sound Output is short circuit Check speaker loads for shorts Input is overloaded Reduce input level at source Output is being over driven Reduce volume levels on front panel Bass control is turned up Reduce Bass control level Volume controls down Check volume controls Amplifier has overhe
FUNCTIONAL NOTES AND INTERNAL ADJUSTMENTS Priority Channel 1 will mute channels 2, 3 and 4. This will only occur when signal appears on channel 1, irrespective of the channel volume control. Priority can be disabled. (See below). The release time is approx. 3 secs and is NOT adjustable. The mute depth is approx. 40dB and is not adjustable.
DIMENSIONS AMC+ SERIES INSTALLATION AND OPERATION MANUAL PAGE 9
SPECIFICATIONS AMC+ 30 AMC+ 60 AMC+ 120 AMC+ 250 30W 60W 120W 250W > 75dBr > 75dBr > 80dBr >85dBr 85Hz-15kHz 75Hz-15kHz 75Hz-15kHz 30Hz-20kHz 1.0A 0.5A 1.6A (x2) 3.15A 1.6A 4A 4A 2A 8A 6.3A 3.15A 10A (x2) 96% 93% 93% 90% 482 x 88 x 190mm 19” x 3.5” x 7.5” 482 x 88 x 281mm 19” x 3.5” x 11.1” 482 x 88 x 281mm 19” x 3.5” x 11.1” 482 x 88 x 384mm 19” x 3.5” 15.1” Net Weight 6.0kg 13.2lb 8.5kg 18.7lb 10.5kg 23.1lb 11.5kg 25.3lb Shipping Weight 7.5kg 16.5lb 10.5kg 23.1lb 12.
SPECIFICATIONS COMMON TO ALL MODELS Thd (1khz, -1db) Better than 0.5% Mic Input SENSITIVITY IMPEDANCE HEADROOM 1mV @ 200ohm 1k3 ohm 77mV (37dB) Aux Input SENSITIVITY IMPEDANCE HEADROOM 150mV >200kohm > 15V (>40dB) Tone Control BASS @ 100HZ TREBLE @ 10KHZ +/- 12 dB +/- 9 dB Line Out NOMINAL OUTPUT OUTPUT IMPEDANCE 0.
ENGINEERED BY AUSTRALIAN MONITOR Address: 1 Clyde Street, Silverwater, Sydney NSW 2128 Australia. Private Bag 149, Silverwater NSW 1811 ABN 78 001 345 482 Website: www.australianmonitor.com.au International enquiries email: international@australianmonitor.com.au DISTRIBUTED IN AUSTRALIA AND NEW ZEALAND BY HILLS SVL www.hillssvl.com.au NSW P: 02 9647 1411 E: nsw@hillssvl.com.au QLD P: 07 3852 1312 E: qld@hillssvl.com.au ACT P: 02 6260 4544 E: act@hillssvl.com.au WA P: 08 9204 0200 E: wa@hillssvl.com.