Instruction Manual

P.28
UM-UV-621-MCS-Q114V1 www.austin-hughes.com
Header Command
ID
Val 1 Val 2 Val 3 Val 4 Val 5 Val 6
Checksum
Footer
0x06, 0x4D,0x43 0x52 P.Swp 0x00 0x00 0x00 0x00 0x00 0x0D, 0x0A
Set PIP Swap
• Function
The computer swaps the main screen with PIP screen
The PIP function may or not be available on a particular LCD display depending on the model selected
Available only when the PIP function is ON
Header Command
ID
Val 1 Val 2 Val 3 Val 4 Val 5 Val 6
Checksum
Footer
0x4D, 0x43,0x06 0x52 P.Swp 0x00 0x00 0x00 0x00 0x00 0x0D, 0x0A
• Ack
P.Swp : 0x00 ( always )
Header Command
ID
Val 1 Val 2 Val 3 Val 4 Val 5 Val 6
Checksum
Footer
0x4D, 0x43,0x15 0x52 ERR 0x00 0x00 0x00 0x00 0x00 0x0D, 0x0A
• Nak
< 2.23 > PIP Swap Control