Using the dip switch no. 1, 2, 3, & 4 to setup each EC box level level as below :
Cascaded EC boxes Dip switch no.
12345678
1st level
Master EC box On On On On Off Off Off Off
2nd level Slave EC box Off On On On Off Off Off Off
3rd level Slave EC box On Off On On Off Off Off Off
4th level Slave EC box Off Off On On Off Off Off Off
5th level Slave EC box On On Off On Off Off Off Off
6th level Slave EC box Off On Off On Off Off Off Off
7th level Slave EC box On Off Off On Off Off Off Off
8th level Slave EC box Off Off Off On Off Off Off Off
9th level Slave EC box On On On Off Off Off Off Off
10th level Slave EC box Off On On Off Off Off Off Off
11th level Slave EC box On Off On Off Off Off Off Off
12th level Slave EC box Off Off On Off Off Off Off Off
13th level Slave EC box On On Off Off Off Off Off Off
14th level Slave EC box Off On Off Off Off Off Off Off
15th level Slave EC box On Off Off Off Off Off Off Off
16th level Slave EC box Off Off Off Off Off Off Off Off
Daisy chain level setting
ON
OFF
** No. 5, 6, 7 & 8 dip switch reserved
Steps :
■ Only Master EC Box built-in IP remote access module.
■ Master EC Box MUST be set on the 1st daisy chain level according to the table below.
■ For the 2nd - 16th levels ( slave EC box ), please make the level setting according to the table below.
■ For the cabling connection, please refer to the next page.
< 1.5 > EC Box Level Setting