WDH-1920EA WARNING · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 2-3 CAUTIONS · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 4-5 DESCRIPTION OF COMPONENTS / FUNCTION EXPLANATION · · · · · · · · · · · · · · · · · · · · · · 6 OPERATING INSTRUCTIONS · · · · · · · · · · · · · · · · · · · · 7 CONTINUOUS DRAINAGE OPTIONS · · · · · · · · · · · · · · 8 MAINTENANCE / EMERGENCY · · · · · · · · · · · · · · · · · · 9 R290 AUTHORISED REPAIRER INSTRUCTIONS · · · 10-13 SPECIFICATIONS
WARNING • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. • Children shall be supervised to ensure they do not play with the appliance.
WARNING Additional warnings for appliances with R290 refrigerant gas (refer to the rating plate located at rear of the appliance for the type of refrigerant gas used). READ THE MANUAL CAREFULLY BEFORE USING THE APPLIANCE • R290 refrigerant gas complies with European environmental directives. • This appliance contains approx. 0.115 kg of R290 refrigerant gas. The maximum charge amount is 0.3 kg. • The minimum rated airflow is 148 m³/h.
CAUTIONS Do not fold the power cord as shown below. Make sure the plug is placed fully & firm into the socket. Do not use multiple sockets as shown below. Make sure the plug is clean. After turning the unit off, please take plug out of the socket. Do not have wet hands when connecting the power plug. If the power cord on this unit is damaged it must be replaced by the manufacturer, it’s service agent or qualified persons in order to avoid a hazard.
CAUTIONS Do not pull the power cord, which may break and cause danger. Do not use insect, oil or paint spray around the machine. They might cause damage to the plastic parts or start a fire. Do not place the machine on uneven ground. This may cause shaking, noise and leakage of water. Keep the unit 20cm away from the wall to dissipate the heat properly. It is dangerous to put anything into the machine. Close all windows and doors to assist with the efficiency of removing moisture.
DESCRIPTION OF COMPONENTS DEHUMIDIFIED DRY AIR VENT CONTROL PANEL HANDLE MOIST AIR INTAKE FRONT PANEL AIR FILTER DRAIN BUCKET ROLL CASTORS CONTINUOUS DRAINAGE OUTLET PEAR PANEL FUNCTION EXPLANATION HUMIDITY SET KEY To set the humidity, press the key to select the desired setting. The sequence is : 60% -> 50% -> 40% -> CONTINUE -> 60% BUCKET FULL LAMP When the bucket is full, the bucket full indicator will be on and the dehumidifier will stop operating.
OPERATING INSTRUCTIONS ● Start Operation 1) Ensure that the unit is connected to the power socket. 2) Make sure the water tank is placed in proper position (when plugged in for the first time the full tank lamp may light up. If so, just pull out the water tank then push it back to the proper position). " to select humidity setting. 3) Press the power control to turn on the machine. Press " If the indoor humidity is over the set humidity, the machine will start removing moisture.
CONTINUOUS DRAINAGE OPTIONS Continuous drainage is an additional method of removing collected water from the dehumidifier. Instead of manually emptying the water tank, the User may choose this method to allow the water to bypass the water tank and flow directly from the dehumidifier via a drain hose. The following steps are useful when there are good conditions for drainage near the dehumidifier. Drain hose Back of the unit 1. Prepare hose to drain out water. The hose has inner diameter of 13mm.
MAINTENANCE Air filter cleans the dust and impurities from the air which may hinder the dehumidifying function, these should be regularly cleaned. The filter is located behind the rear grill and should be pulled outwards from the top to remove. Clean with a vacuum cleaner or wash it with clean water and dry with a dry cloth. Replace filter and continue to operate the dehumidifier. EMERGENCY If a problem occurs, switch off and unplug the unit immediately.
INSTRUCTION FOR REPAIRING APPLIANCES CONTAINING R 290 AUTHORISED PERSONS ONLY! 1. Checks to the area Prior to beginning any authorised work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. The following precautions shall be complied with prior to conducting work on the system. 2.
INSTRUCTION FOR REPAIRING APPLIANCES CONTAINING R 290 AUTHORISED PERSONS ONLY! - that capacitors are discharged; this shall be done in a safe manner to avoid possibility of sparking. - that there are no live electrical components and wiring are exposed while charging, recovering or purging the system; - that there is continuity of earth bonding. 10.
INSTRUCTION FOR REPAIRING APPLIANCES CONTAINING R 290 AUTHORISED PERSONS ONLY! Oxygen free nitrogen (OFN) shall then be purged through the system both before and during the brazing process. 15. Removal and evacuation When breaking into the refrigerant circuit to make repairs – or for any other purpose – conventional procedures shall be used. However, it is important that the best practise is followed since flammability is a consideration.
INSTRUCTION FOR REPAIRING APPLIANCES CONTAINING R 290 AUTHORISED PERSONS ONLY! f) Make sure the cylinder is situated on the scales before recovery takes place. g) Start the recovery machine and operate in accordance with manufacturer's instructions. h) Do not overfill cylinders. (no more than 80% volume liquid charge). i) Do not exceed the maximum working pressure of the cylinder, even temporarily.
SPECIFICATIONS WDH-1920EA 390 W 25 0.115 kg SAA approval Certificate No.: SAA-210779-EA 328 x 516 x 219 mm 12.6 kg Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check your local authority of retailer for recycling advice.