Technical data

79
Confidential
Topology 1-Phase string inverters
Transformerless Technology Minimizing losses and increasing conversion efficiency.
Other adventages of “Dual Stage” topology:
The inverter always operates in maximal efficiency region
Extrem wide input voltage range combined with flat efficiency curve
Array can be split in 2 independent subarrays each with stand-alone maximum power point
tracking.
PV PV
PVPV
PVPV
INVERTER
DC IN 1
AC
OUT
_
DC ELECTRICAL PANEL
Continuous Equipment Ground
kWh
UTILITY - LOW VOLTAGE GRID
BUY/SELL
METER - M2
RESIDENTIAL
ELECTRICAL PANEL
TO LOADS
MAIN HOUSE
GROUNDING SYSTEM
PV1-PV18
PHOTO VOLTAIC
MODULES
EXTERNAL
DISCONNECT
BOX
SS1
SS2
CB1
CB2CB3CB4CBn
S2
GAS
ARRESTOR
Booster1
Booster 2
EMI FILTER
DC+AC
GFCI
F1
F2
S1
+
+
-
-
DC IN 2
kWh
Riso