Technical data

43
Confidential
String Inverters
PVI-6, 8, 10 and 12.5 kW Three phase
PVI-6.0-TL-OUTD PVI-8.0-TL-OUTD PVI-10.0-OUTD PVI-12.5-OUTD
Input parametrs (DC Side)
Rated DC Power [kW]
6.2 8,25 10.4 13.0
Maximal recommended DC Power [kW]
6.8 9 11.4 14.3
Input voltage range [V]
0.7x VStart - 850 (580 rated)
Full power MPP range [V]
200 - 750 270 - 750 300 - 750 360 - 750
Full asymm. Operation MPP range
250 750 @ 4.2kW 320 750 @ 5.5kW 360-750 @ 6.5kW 445-750 @8kW
Max. Input Voltage [V]
900
Input Activation Voltagan VStart [V]
360 default (Adjustable 250 - 500 via Display and Software)
Number of independent MPP inputs
2 2 2 2
Maximal Input Power per MPPT [kW]
4.2 5.5 6.5 8.0
Number of DC Inputs ( Connection pairs)
2 (-S Version) 3 (Standard or -FS Version) for each MPPT
Maximal Input Current per MPPT [A]
17 (22 Short circuit) 18 (22 Short circiuit)
DC Varistor
4 (2 for each MPPT)
DC Switch
Integrated (for S- and FS-versions)
AURORA® PVI-6.0/8.0/10.0/12.5-TL-OUTD