Technical data
Step-by-step configuration procedure for photovoltaic generator with Aurora Designer
Step 1.1 – Inverter characteristics
In the section Inverter data are summarized the
inverter characteristic parameters used for verifying the
configuration.
Basic parameters:
•Max voltage Voc: maximum input voltage for proper
operation (Input OV alarm generation threshold)
•Activation voltage(rated)
•MPPT rated current
Step 1.2 – Panel Characteristics
The Panel data section summarises the panel
characteristic parameters used for the configuration.
NOTE: it is recommended to verify that the electrical
parameters of the selected module are aligned with the
electrical parameters in the data sheet of your module.
What to do if the panel is not on the list?
•Enter the module in the database using the “Add Module” sheet
•Send an e-mail to service@power-one.com with the panel datasheet in attachment: this way the new panel will be entered
into the database and the configurator thus updated will be sent back and added on our website.
Dimensioning systems with Power-One inverters