Effective January 2003 INSTALLATION & OPERATING INSTRUCTIONS Serial Number: The Australian Gas Association Approval No. 4553/AG103 Australian Patent PN 200110001S B.D. Number: Model: IS100 Model: FSP100 Model: FS100 Model: IS200 PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Model: FSC100 Aurora CLIMATE SYSTEMS A.B.N.
TABLE OF CONTENTS SAFETY LABEL Warranty Installation Service Safety Labels OPERATING INSTRUCTIONS 2 Automatic Humidifier Operation 35 3-4 Operating Instructions Checklist 36-37 INSTALLATION INSTRUCTIONS Specifications 5-6-7-8 General Safety Information 9 Clearances to Combustibles 10 Log Installation Fluing Requirements 11-12-13 Lighting Instructions 38 Fan Operation 39 Shutdown Instructions 39 High Temperature Cut Out 40 Paint Curing - First Firing Operating Faults 40 41 Resetting
TO THE NEW OWNER Congratulations! You are the owner of a state of the art Archer High Efficiency Gas Log Space Heater. This appliance has been designed to provide you with all the warmth and charm of a wood fire at the flick of a switch. The Archer Gas Log Space Heater promises to provide you with the highest economy, heat output, comfort and security.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE ! IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL FOR ASSISTANCE OR ADDITIONAL INFORMATION, CONTACT AURORA CLMATE SYSTEMS. TELEPHONE NUMBER (03) 9795 8895 THIS APPLIANCE MUST BE INSTALLED OR SERVICED ONLY BY A LICENCED GAS FITTER FOR THE INSTALLATION AND/OR SERVICE OF THE ARCHER GAS LOG SPACE HEATER.
SAFETY LABELS Model - Archer Gas Type Model Type Gas Consumption Manifold Pressure Injector Size - Front - Rear A.G.A Approval No to Code AG103 Electrical conforms to AS3100 Ο Ο Natural FS100 Ο FSP101 Ο IS102 Ο 30MjHr 0.8Kpa 1.6mm 2.4mm 5446 LPG FS100 Ο FSP101 Ο IS102 Ο 30MjHr 1.5Kpa 1.1mm 1.5mm 5446 240V 50 Hz Manufactured by Aurora Climate Systems A.B.N.
SPECIFICATIONS - MODEL NO. FS101/P200 1 Flue Outlet 40mm ø Pipe Heater with Pedestal and Single Flue Adaptor 2 Air Inlet 3 Electric Cord 4 1/2 “ BSP Connection (Inside) 5 Single Flue Adaptor 45 716 157 443 23 2 1 4 858 3 C/L Flue 409 317 283 323 317 220 697 435 5 SPECIFICATIONS - MODEL NO.
SPECIFICATIONS - MODEL NO.
SPECIFICATIONS - MODEL NO. IS100 Fireplace Insert with Mantel surround IS001 (1100 x 858) with standard top panel.
SPECIFICATIONS - MODEL NO. IS200 Fireplace Insert with Mantel surround IS002 (900 x 758) with cut-back top panel.
INSTALLATION INSTRUCTIONS GENERAL SAFETY INFORMATION 1. This installation must conform with local codes or, in the absence of local codes, with AG 601 2. Provide adequate clearances around the product for servicing and ensure there are no obstructions to the combustion air intake situated at the back of the heater. (Refer Page 6 item 2) 3. The appliance must be installed on a flat, solid continuous surface (ie. wood, metal, concrete).
INSTALLATION INSTRUCTIONS CLEARANCE TO COMBUSTIBLES Freestanding models FS100 - FSP101 A B C B C Freestanding Units A Rear Wall to Unit 25mm B Side Wall to Unit 15mm C Corner Installation 0mm Fireplace Insert Model IS100 A B B Zero clearance No hearth required Note: The Archer Gas Log Space Heater has been tested and approved for zero clearance to combustible materials.
INSTALLATION INSTRUCTIONS LOG INSTALLATION The gas log set (front/middle log and rear log) is pre-set and installed in the factory. Only the left and right hand cross logs are packaged separately inside the firebox for installation by the installer. 1. To access the log set parcel, lift off top panel and remove the 2 screws in the left hand and right hand side front panel on the top, which hold the left hand and right hand side front panel. 2.
INSTALLATION INSTRUCTIONS LOG SET DIAGRAM - A The Gas Log Kit contains the following: 1) 2) 3) 4) Rear Log Front/Middle Log R/H Cross Log L/H Cross Log 4 3 Note: Location Pin has been fitted to Rear Log (1) to hold L/H Cross Log (4) in position. 1 2 INSTALLERS - PLEASE NOTE (A) LOG SETTINGS Do not remove logs from heater unless absolutely necessary!! Logs have been preset and aligned for correct performance. Only place cross logs in position as per instructions above.
INSTALLATION INSTRUCTIONS (Side view main logs and burners) 1. Rear Log 2. Front/Middle Log 3. Rear Burner 4. Front Burner 1 2 NOTE: 4 2 3 Do not change position of rear logs and front/middle logs as their positions have been present at the factory. Changing log positions will result in faulty gas burner function.
INSTALLATION INSTRUCTIONS FLUING REQUIREMENTS Co-Axial Flue Installations Note: This appliance has only been approved for co-axial flue application if the flue (as supplied by the manufacturer) is installed to an external wall or external fireplace. (Refer installation diagram for Co-Axial Flue Installations Pages 16-17-18-19-24).
SINGLE FLUE KIT FOR ARCHER GAS LOG SPACE HEATER For applications on Flexible Single Flue refer pages 24-25-26 No Description Qty 1 Single Flue Adaptor 1 Supplied with heater 2 40mm ø PVC Pipe 400mm long 1 Supplied with heater 3 90° PVC Bend 1 Supplied with heater 4 40mm ø PVC Pipe 5 Stainless Steel Cowl 1 Supplied with heater 6 Self Tapping Screws 4 x ½" 4 Supplied with heater Supplied by installer 5 4 6 1 2 3 15
CO-AXIAL FLUE KIT FOR ARCHER GAS LOG SPACE HEATER For applications refer pages 17-18-19 of this Installation Manual. No Description Qty 1 Co-Axial Manifold Starter 1 2 Internal Pipe Spacers 3 3 40mm ø PVC Pipe 400mm 4 65mm ø PVC Pipe 400mm 5 Stainless Steel Co-Axial Cowl Approx. 1 2 3 5 2 Mounting Plate 1 4 15mm Use 4 self tapping screws provided with assembly 4mm ø x 15mm long.
INSTALLATION INSTRUCTIONS Installation External Wall - Including High Rise Apartments Using Co-Axial Flue Kit Freestanding Heater without Pedestal Model FS100 For installation details refer Page 16 - Co-Axial Flue Installation 1 5 2 3 C/L Flue Floor Protection No Hearth Required 1. 2. 3. 4. 5. 4 97 Installation zero clearance to combustibles. Note: Allow 30mm for clearance to rear wall for Co-Axial Flue Adaptor.
INSTALLATION INSTRUCTIONS Freestanding Model with Pedestal Installation FSP101 - External Wall including High Rise Apartments using Co-Axial Flue Kit For installation details refer Page 16 - Co-Axial Flue Installation 1 5 2 3 C/L Flue 4 317 Floor Protection No Hearth Required 1. 2. 3. 4. 5.
INSTALLATION INSTRUCTIONS Insert Models IS100/IS200 -With Co-Axial Flue - Exterior Masonary Fireplace For Installation instructions refer Page 16 - Co-Axial Flue Installation Co axial Flue Pipe up to 1 metre long Refer Page 16 1/2” BSP Gas Connection Refer Page 29 Note: Do not use PVC cement to seal flue pipe connections to allow for removal of flue pipe. Incorporate loop in gas connection or use flexible hose for gas connection to allow for removing of appliance from fireplace.
INSTALLATION INSTRUCTIONS Freestanding Unit Installation - with Single 40mm PVC Flue Pipe using 75mm Cowl For External and Internal Wall Applications (Flue Kit Assembly is supplied complete - under Stock Order Code SFA001) Correct Installation Incorrect Installation Correct: Cowl to suit 40mm PVC Flue Pipe supplied in flue kit SFA001. 40mm PVC Flue Pipe to be supplied by installer. Correct: 40mm PVC Flue Pipe to have upward slope to avoid water trap in 90°elbow.
INSTALLATION INSTRUCTIONS Freestanding Internal Wall Installation Models FS100 - FSP101 - Using Single 40mm ø PVC Flue Pipe For External and Internal wall applications Freestanding Models with and without Pedestal Refer Page 20 for correct installation instructions 2 3 500mm Roof 4 5100mm MAX Internal Wall 5 NOTE: All flue pipe connections need to be sealed with PVC cement, except connection of 40mm ø pipe item 7 to flue fan outlet. 150mm 80mm 6 1 1. 2. 3. 4. 5. 6. 7.
INSTALLATION INSTRUCTIONS Internal to External Wall Installation using 40mm ø PVC Flue. Side Wall Installation (Horizontal Single Flue) External Wall Internal Wall 90º Elbow 75mm stainless steel cowl to suit 40mm PVC flue pipe. Gas Line Concrete Slab CAUTION: 40mm PVC Pipe PLEASE DO NOT ALLOW WATER TRAPS TO FORM IN FLUE OR HEATER WILL CEASE TO OPERATE. Note: Total installation length in 40mm ø PVC pipe 5100mm with 1 x 90º and 2 x 45º bends.
INSTALLATION INSTRUCTIONS Internal Wall Under Floor Installation using 40mm ø PVC Flue. Internal Wall External Wall 90º Elbow 75mm stainless steel cowl to suit 40mm PVC flue pipe. 90º Elbow Note: All flue pipe connections need to be sealed with PVC cement, except Flue Fan Connection. Note: Total installation length in 40mm ø PVC pipe 5100mm with 1 x 90º and 2 x 45º bends.
CREATED FIREPLACE MODEL IS100/IS200 Zero clearance, power flue, single 40mm flue and shallow unit depth allow you to create your own fireplace anywhere in your home with your choice of mantel. Note: Heater must be able to be removed easily for servicing. (Not locked in) 1 2 500mm 6 5 5100mm Maximum 4 4 7 9 8 1 2 3 97mm 97mm 3 INTERNAL WALL APPLICATION EXTERNAL WALL APPLICATION 1. 2. 3. 4. 5. 6. 7. 8. 9. 1. 2. 3. 4.
INSTALLATION INSTRUCTIONS Flexible Flue Kit to suit Fireplace Insert Installations Model IS100/IS200 STANDARD FLUE KIT SUPPLIED BY AURORA FOR INSERT INSTALLATION (SFA002) Note: Standard 75mm Cowl to fit 40mm ø pipe is also supplied with flue kit. 40mm N.B. Plain Coupling (Supplied with Flue Kit) (38mm I.D.) 50mm Nylaflow Flexible Hose Nylaflow G.P. Hose Code AH50WAS (Supplied with Flue Kit SFA002) 40mm N.B. SWV Pipe (Not Supplied) 60mm S.S. Hose Clamp Note: I.D.
INSTALLATION INSTRUCTIONS Fireplace Insert Installation Model IS100 -Using Aurora Flexible Flue Kit SFA002 with Single 40mm PVC Flue Pipe using 75mm cowl Fasten 40mm Flue Pipe with bracket to stop flue pipe being forced downwards ( Supplied by Installer) Gas Cowl Supplied in flue kit 200mm Galv Sheet Flashing to seal chimney (Supplied by Installer) 40mm PVC Pipe SWV (Supplied by Installer) 2 x 45º PVC bends 40mm (Supplied by Installer if required) 5100mm MAX Aurora flexible flue kit SFA002 Use 1/2” g
OPTIONAL REMOTE CONTROL THERMOSTAT An optional programmable Remote Control Thermostat can be fitted to the heater at the factory when ordered or even after the heater has been installed. See your Archer dealer for correct type. Installation:The Remote Control can be installed by the owner of the heater if required. The Remote Control is a battery operated device, which requires a small amount of low voltage plug in wiring.
ARCHER GAS LOG SPACE HEATER INSTALLATION OF THE REMOTE RECEIVER AND FRONT FLAME DISPLAY BUTTON Effective 13th April 2005 VIOLET Caution: Please make sure heater is unplugged when installing Remote Control Please Note: The front panel must be opened for this wiring to occur. The front panel simply pulls forward - no tools required. RED BUTTON Caution when removing front panel as there are low voltage wires attached to the inside of the front panel.
INSTALLATION INSTRUCTIONS GAS CONNECTION (Line Supply) The gas connection is 1/2” BSP supplied in heater. GAS SUPPLY LINE TO HEATER a) b) c) d) e) Remove top panel from heater by lifting top panel. Remove the 2 screws on top L/H front side panel and lift out side panel. Remove rubber grommet from back panel of heater and insert 1/2” copper gas supply line through back panel of heater. Connect gas supply line to flexible gas hose. Ensure that flexible gas hose is not kinked after fitting gas supply line.
INSTALLATION INSTRUCTIONS GAS VALVE PRESSURE ADJUSTMENT The gas valve pressure adjustments must be checked during installation, and if necessary corrected to suit the gas type available. (Reference Page 12) “A” represents the main regulator adjusting screw pressure to burners. Access to this screw is obtained by removing the brass screw cover; use a flat blade screw driver for adjustment of gas pressure.
ARCHER 2004 WIRING DIAGRAM 240V 50 Hz TRANSFORMER 240V 240 V ACTIVE BROWN EARTH GREEN CONVECTION FAN (2) TR.PRIMARY BLACK TR.PRIMARY WHITE (8) 240 V NEUTRAL BLUE J1 NEUTRAL ( 7-5-3 ) PIN 18 HSI HSI PIN 16 0.47 uF PIN 6 1 uF PIN 4 F OVER TEMP .80 C R FRONT AND REAR GAS VALVES M 25 1 0 FRONT BURNER SWITCH PIN 5 14 WAY RIBBON TO DISPLAY PIN 20 CONV.FAN.BLACK ( 13 ) (1) CONV.FAN.BLUE MAIN GAS VALVE E 8 REAR.H.S.I. (19) (20) GAS.VALVES.ACTIVE FRONT.H.S.I. (17) (18) REAR.H.S.I. LOW.
INSTALLATION INSTRUCTIONS MAIN DOOR SAFETY SCREEN INSTALLATION ! CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE FROM THE MAIN DOOR GLASS AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE. ALWAYS ENSURE THAT YOUR SAFETY SCREEN SUPPLIED WITH THE HEATER IS FITTED TO THE MAIN FRONT DOOR OF THE HEATER.
INSTALLATION INSTRUCTIONS Heater surround Fireplace Insert Installation 1. Remove Fireplace Insert Surround assembly from carton, handle insert surround with care to avoid paint damage. 2. Assemble Fireplace Insert Surround as per diagram with 4 of 8 gauges x 3/8” self-tapping screw supplied.
INSTALLATION INSTRUCTIONS Optional Pedestal Assembly Installation 1. 2. 3. Remove pedestal assembly from carton. Handle pedestal with care to avoid paint damage. Place pedestal assembly into position where heater is to be located. Lift and place main body of heater on top of pedestal assembly and locate main body of heater into locating points provided on pedestal assembly.
AUTOMATIC HUMIDIFIER OPERATION Most gas heaters dry out the air in the room. (Remember the bowls of water in front of the old gas heaters?) The Archer has ingeniously solved this problem with an Automatic Humidifier. Gas contains moisture which is normally expelled out the flue or chimney after combustion. But the Archer is so efficient by taking 92% of the heat out of the burnt gases that the moisture drops out and condenses in the back of the heater.
OPERATING INSTRUCTIONS CHECKLIST BEFORE OPERATING THIS APPLIANCE, CAREFULLY PROCEED THROUGH THE FOLLOWING CHECK LIST. 1. Read and understand these instructions before installing or operating this appliance. 2. Installation of this appliance is only to be carried out by a licensed gas fitter who preferably should be familiar with the installation of the Archer Heater. 3.
OPERATING INSTRUCTIONS CHECKLIST cont... 11. Prior to operating the appliance check for dust or particles lying on top of the burners. Refer Page 11 item 5. 12. Check and verify that logs are placed correctly as per instructions on Pages 12-13 of this Installation Manual. If logs are incorrectly positioned or placed wrongly it can create a hazardous situation, and in most instances, the heater will not operate correctly. 13. Do not light heater without logs fitted, as heater will not operate. 14.
LIGHTING INSTRUCTIONS 1. Main Electrical power supply must always be switched on to the unit with the two burner switches in the off position (up) before commencing lighting the heater. 2. Turn on main gas supply. 3. Verify that main electrical supply is switched on by checking the 240V AC power status display indication is on. 4. Burner selection: select low burn, medium burn, or high burn. Low burn switch (Item 1) controls the f r o n t burner only.
FAN OPERATION The 3-speed main convection fan will cut in automatically approximately 3 to 5 minutes after the heater has warmed up. Note: The 3-speed main convection fan is automatically controlled and will operate on three preset speeds. Depending on your burner setting and the surrounding ambient temperature, the L.E.D lights (Items 7, 8 and 9) for the fan will light up. The bottom L.E.D light (Item 7) is low speed setting, and middle L.E.
OVER TEMPERATURE CUT OUT The Archer Gas Log Space Heater is protected against overheating with a high temperature 80° cut out switch to protect the heat exchanger, plastic sump and flue fan. The high temperature cut out switch will automatically switch off the gas supply to the heater, if the temperature in the room where the heater is located reaches approximately 28°C. The heater will go into lock out mode.
UNIT OPERATING FAULTS SERVICE AND INSTALLATION OF THE APPLIANCE SHOULD BE CARRIED OUT BY AUTHORISED PERSONNEL ONLY. THE MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS LOG SPACE HEATERS IS IMPROPER GAS PRESSURE, INCORRECT LOG PLACEMENT, IMPROPER INSTALLATION, INCORRECT FLUE INSTALLATION, INCORRECT SWITCHING OF BURNERS, DIPS/SPIKES IN THE INCOMING POWER OR REVERSE POLARITY’S.
MAINTENANCE Note: Your appliance should be inspected, serviced and checked annually by a qualified service person to ensure that your appliance is operating safe and efficiently. Should you detect any abnormality in the operation of your appliance call a qualified service person who has been trained and approved to inspect and service the appliance. This may be your installer or dealer.
GOLD PLATED DOOR/ CHROME PLATED DOORS The gold and chrome plated finish on the door requires little maintenance and needs only to be cleaned with a soft cloth and a small amount of Mr Sheen. Polish gently. Please note: Stains or imperfections on plated finishes are not covered under warranty. Caution: Do not use abrasive materials or chemical cleaners as they will harm the gold and chrome plated finish and void the warranty. Clean any fingerprints off before turning the unit on.
AUTOMATIC CONTROL FLAME SAFEGUARD SYSTEM SPECIFICATIONS MODEL: Aurora Climate Systems - ignition, operations pack. Model: AM3 TW-35S TS-5S 240 V 50-60 Hz 2.5VA CLASS: 2A Programming without reignition. Safety shut-down within 2 seconds. DIMENTIONS: L = 145 W = 90 H = 50 Resistant to 85 degrees C UL94VO materials or ABS Free or wall mounting.
COMPLETE UNIT WARRANTY DESCRIPTION WARRANTY PERIOD (FROM DATE OF PURCHASE) Heat Exchanger Main Convection Fan All Other Parts 5 Years Parts/1 Year Labour 2 Years Parts/1 Year Labour 1 Year Parts/1 Year Labour AURORA WARRANTY PROGRAM To qualify for the Aurora Warranty Program, you need to fill out the warranty registration form, and have your qualified installer fill out the Installation Commissioning Report. Both documents must be returned promptly to Aurora Climate Systems.
CONDITIONS, EXCLUSIONS AND QUALIFICATIONS cont... 6. Aurora further assumes no liability for defects or damage caused by incorrect operating or performance of the appliance caused by any modification or incorrect installation. Unauthorised components or installation modifications could create a fire hazard by altering the safety design of the Gas Log Space Heater. Flue Installation 7.
THIS WARRANTY DOES NOT APPLY TO THE FOLLOWING: 1. Breakage of glass components, door glass imperfections, (i.e. glazing, breakage or discolouring. 2. Corrosion, chips, scratches, blistering, fading, paint, metal finish imperfections or rusting due to the exposure of the appliance to man made or adverse natural atmospheric conditions or poor handling by the freight company, the installer or the customer. 3.
ATTENTION APPLIANCE INSTALLER PLEASE RETURN THESE OPERATING & INSTALLATION INSTRUCTIONS TO THE CONSUMER (FOR FUTURE REFERENCE) DATE OF PURCHASE